User Manual

9
10
Under the setting condition. Then you can press "SET" button to set hot
-air rework station' s temperature and the main temperature area shines
the setting temperature, you can press UP knob or DOWN knob to adjust
the setting temperature. 4s-no-press or press SET knob, you can keep the
temperature and quit out this setting. (Diagram 6).
A. Setting temperature via handle of rework station. You can press UP knob
or DOWN knob directly to adjust temperature and the main temperature
area indicators setting temperature. 4s-no-press or press SET knob, you
can keep the temperature and quit out this setting, at that time, you can
adjust hot-air volume by pressing " " Whether screen A or screen B
shine as you set, the device is under the setting condition and
shining area for switch to screen "A " automatically.
Notice: continually pressing UP or DOWN knob in long time will quickly adjust
the temperature, at that time, the screen don't shine. (Same as below description)
In normal working condition, there are two methods to set hot-air volume:
A. If screen A shines setting temperature through operating the
button of panel. If screen A doesn't shine you must press the "SET"
button to switch to shine of screen A then the station under the
setting condition. Then you can press "SET" button to set hot-air rework
station' s temperature and the main temperature area shines the setting
temperature, you can press UP knob or DOWN knob to adjust the setting
temperature. 4s-no-press or press SET knob, you can keep the
temperature and quit out this setting (diagram 7).
B. Setting hot-air volume via handle of rework station. You can press UP
knob or DOWN knob to adjust hot-air volume and the main temperature
area indicators setting volume. 4s-no-press or press SET knob, you can
keep the volume and quit out this setting, at that time, you can adjust
hot-air volume by pressing " " When the screen A or screen B shine
as you set, the device is under the setting condition and shining
area for switch to screen"A" automatically.
4.Hot-air volume settings
5. Storing the Temperature values
Under normal working condition, hold down POWER knob at the left of panel,
at the same time long press (>5s) the UP knob or DOWN or SET to adjust
temperature and air volume to the required values separately in term 1 or
term 2 or term 3. But when you hold down POWER knob at the left of panel and
short press (<5s) UP or DOWN or SET knob to use the storage setting
temperature and air volume into current work temperature and air volume
(diagram8, diagram9, diagram10).
(Notice: up, down, set refer to storage term 1, term 2, term 3)
(diagram 6)
(diagram 7)
(diagram 8)
(diagram 9) (diagram 10)
Screen A:
Working state of shortcut 1
Screen A:
Working state of shortcut 2
Screen A:
Working state of shortcut 3
6.Temperature comp temperature and calibration
Under normal working condition, hold down both POWER knob at left of
panel and " " knob on the handle to calibrate. Screen A will display the
character CAL, and temperature value can be calibrated by pressing UP or
DOWN knobs. Pressing the SET knob to confirm storage and quit from this
calibration (diagram 11).