User Manual

11
12
(diagram 11)
Under normal working condition, when the user put the handle on the bracket,
then the equipment will be automatically switch to the dormancy condition and
the heater also stops heating. This happens in the case when the temperature is
higher than 100 , during the hot-air station dormancy period the screen A
display character SLP (diagram 3)
7. Dormancy
(diagram 3)
Screen A: Standby
In normal condition, continually press " "knob twice and then make the
hot-air be in the state of cold-air blow (diagram12). Under the cold-air
condition, press " " knob once, recover the hot-air working condition.
8.Conversation between cold-air and hot-air
(diagram 12)
Under normal working condition, the device keep the current temperature and
air volume and cut down heating to the rework station after pressing POWER
knob at the left of panel (diagram 1A), below 100 , the device is standby
(diagram1). If power is off, the soldering station is off, whole device will be off
after the temperature below 100 .
9.Standby
(diagram 1A) (diagram 1)
Standby state of screen A
1. When "H-E" is displayed on the screen A, there is no hot air in the nozzle
(diagram13), which indicates that the heating element fails.
2. When "S-E" is displayed on the screen A, there is a fault in sensor
(diagram14), which signifies that there is something wrong with the
sensor or the related circuit of the sensor.
10. Error/Fault indication
Screen A: no hot-air fault Screen A: sensor fault
(diagram 13) (diagram 14)
II. SOLDERING STATION
1.Power on
Screen B which displays actual temperature in 3s displays setting temperature
after pressing POWER knob at the right of panel (diagram15, diagram16).
Screen B:
Temperature Settings
Screen B: heating
In normal working condition, if screen B shines or you at first continually
press SET knob twice to switch to shine , then press the UP or DOWN knob
to adjust temperature. Screen B shines"SET" and the main temperature area
shines the setting temperature of soldering station. Stopping pressing knob or
pressing SET knob confirm and keep settings and quit from this operation
(diagram17).
2.Temperature setting
(diagram 15) (diagram 16)