User's Manual

Transmitting Tag Calibration and Installation
MEMS 3000 HomeStation & Transmitter Installation Guide
4-1
Chapter 4 Transmitting Tag (Tx)
Calibration and Installation
First you will need to calibrate or activate the transmitting tag.
Calibrating the Transmitting Tag
1. Hold the free end of the transmitting tag strap in your hand with the
metal pins pointing towards you.
2. Hold the manual reset device in you other hand, with the two connection
points facing the metal pins.
3. Press the metal pins on the transmitting tag onto the two connection
points on the manual reset device.
4. Holding the manual reset device in this position, press the On button.
The red LED on the manual reset device lights up for 2 seconds and then
flashes for another 2 seconds. The flashing indicates that the
transmitting tag has passed the first phase of its calibration
Note that in case of calibration failure, the red LED on the manual reset
device will light up for 2 seconds and then turn off.
5. Once the calibration pass indication has been verified, place the
transmitting tag on its side onto a non-metal surface with the protruding
side of the body facing upwards.
6. Wait for at least 60 seconds. The MEMS 3000 HomeStation makes an
audible beeping sound once the transmitting tag has passed the
calibration