Installation and Operation Manual Celerity FC host adapters Celerity FC-41EN 4-Gb FC single channel host adapter Celerity FC-42EN 4-Gb FC dual channel host adapter Celerity FC-44ES 4-Gb FC quad channel host adapter Celerity FC-42ES 4-Gb FC dual channel host adapter Celerity FC-41ES 4-Gb FC single channel host adapter Celerity FC-42XS 4-Gb FC dual channel host adapter Celerity FC-41XS 4-Gb FC single channel host adapter Celerity FC-21PS 2-Gb FC single channel host adapter © 2007 ATTO Technolo
Contents 1 ATTO provides Fibre Channel solutions ..........................................1 Celerity FC-41EN Adapter Celerity FC-42EN Adapter Celerity FC-44ES Adapter Celerity FC-42ES Adapter Celerity FC-41ES Adapter Celerity FC-42XS Adapter Celerity FC-41XS Adapter Celerity FC-21PS Adapter Celerity selection guide 2 Fibre Channel is a key technology for storage ................................11 Glossary 3 Installing and updating drivers .........................................................
1 ATTO provides Fibre Channel solutions The ATTO Celerity Fibre Channel family of storage products provides connectivity, intelligence and scalability. Celerity FC host adapters simplify advanced storage networking needs such as switching, backup and data management. Specifically designed to enhance the functionality of third party fabric hardware and software, Celerity FC products are the industry-leading platform for storage connectivity.
Celerity FC-42EN Adapter The Celerity FC-42EN is a dual-channel host adapter, providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/sec.full-duplex per channel, the FC-42EN supports the most demanding application requirements. The FC-42EN takes advantage of the latest in host interconnect technology, PCI Express, a serial, highspeed connection that supports aggregate throughout up to 2 GB/sec.
Celerity FC-44ES Adapter The Celerity FC-44ES uses PCI Express Interconnect and 4-Gigabit Fibre Channel to provide 4-Gb FC speeds of up to 800 MB/sec. per channel. The FC44ES supports high-definition video, rich content databases and other high bandwidth environments. The FC-44ES uses PCI Express, a serial, high-speed connection that supports aggregate throughput up to 4 GB/sec. (x8 PCIe) full-duplex.
Celerity FC-42ES Adapter The Celerity FC-42ES is a dual-channel host adapter providing port density for Enterprise server and workstation applications. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-42ES supports the most demanding application requirements. Additionally the FC-42ES takes advantage of the latest in host interconnect technology, PCI Express, a serial, high-speed connection that supports aggregate throughput up to 4 GB/sec. (x8 PCIe) full-duplex.
Celerity FC-41ES Adapter The Celerity FC-41ES is a single-channel host adapter providing support for the most demanding application requirements. With 4-Gb FC speeds of up to 800 MB/sec. per channel, the FC-41ES is a cost effective connectivity solution for environments requiring maximum throughput. The FC-41ES also takes advantage of the latest in host interconnect technology: PCI Express, a serial, highspeed connection that supports aggregate throughput up to 2 GB/sec. (x4 PCIe) full-duplex.
Celerity FC-42XS Adapter The dual-channel Celerity FC-42XS host adapter provides the highest available throughput for Fibre Channel applications while protecting technology investments via backward compatibility with existing infrastructure. With speeds of up to 800 MB/sec. per channel, the FC42XS is capable of supporting the most intensive data applications.
Celerity FC-41XS Adapter The single-channel Celerity FC-41XS provides speeds of up to 800 MB/sec. using full 4-Gigabit Fibre Channel performance while being fully backwardcompatible with existing 2-GB and 1-Gb Fibre Channel infrastructure, protecting existing technology investments. It is capable of supporting the most dataintense applications. Environmental & physical specifications Hardware specifications • • • • • • • • • • • • • 1 Fibre Channel port 4-Gigabit data transfer rates 800 MB/sec.
Celerity FC-21PS Adapter The Celerity FC-21PS Fibre Channel host adapter provides a single 2-Gb Fibre Channel connection from host devices to the Storage Area Network (SAN) fabric. The FC-21PS supports the leading operating systems, providing a single solution for all connectivity needs.
Celerity selection guide Product Features Fibre Channel Ports FC protocol Maximum Transfer Rate (half duplex) Maximum Transfer Rate (fullduplex) Bus Type Bus Characteristics3 Optical Interface Maximum Cable Length Celerity FC-44ES Celerity FC-42ES FC-42EN Celerity FC-41ES FC-41EN Celerity FC-42XS Celerity FC-41XS Celerity FC-21PS 4 2 1 2 1 1 4-Gb 4-Gb 4-Gb 4-Gb 4-Gb 2-Gb 1.6 GB/sec 800 MB/sec 400 MB/sec 800 MB/sec 400 MB/sec 200 MB/sec 2 GB/sec 1 GB/sec (ES) 1.
10
2 Fibre Channel is a key technology for storage Fibre Channel is a serial communications technology designed to transfer large amounts of data among a variety of hardware systems over long distances. It is a key technology for applications that require shared, high bandwidth access to storage. Fibre Channel provides a logical, point-to-point, serial channel for the transfer of data between a buffer at a source device and a buffer at a destination device.
Term Definition fabric a Fibre Channel switch of two or more Fibre Channel switches interconnected to physically transmit data between any two N_Ports on the switch or switches FC Fibre Channel F_port a port in the Fibre Channel fabric where a N_port may attach FL_port a port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop frame an indivisible unit for transfer of information in Fibre Channel frame header the first field in the frame containing the address and other
3 Installing and updating drivers Before installing your Celerity adapter, you must configure your system to recognize and use it by installing drivers for your operating system.
Upgrading an existing Celerity FC driver 1 Log on to Windows as the System Administrator. 2 Insert your Celerity FC Installation Disk and run autorun.bat 3 In Windows Drivers, select your operating system version. 4 Click on Install Driver. Adding a Celerity FC adapter to an existing installation Note Complete this installation procedure before attaching any devices to the adapter. 1 Complete the steps in Updating hardware flash on page 24 to pre-install the driver.
Creating a Celerity FC installation floppy Note You must have a floppy disk with the Celerity FC driver software to install a fresh copy of the Windows OS onto a disk attached to a Celerity FC adapter. 1 Insert the Installation CD into a CD-ROM. The installation starts automatically. Creating a floppy disk from a download 1 Download the latest driver software from the ATTO website, www.attotech.com. 2 The download is a self-extracting executable that expands the driver software package.
16
4 Hardware installation You need a basic understanding of Fibre Channel before installing the Celerity FC host adapter. Please refer to Fibre Channel is a key technology for storage on page 11 for a list of related websites. WWN 0 WWN 1: WWN 2 WWN 3 CAUTION Back up your system data before changing or installing any hardware. System requirements The Celerity FC host adapter package contains the host adapter, the ATTO Utilities CD and a warranty and registration card.
Bracket details Exhibit 4-1 adapters FC-41EN low profile and full height Exhibit 4-3 FC-44ES Adapter Exhibit 4-2 adapters FC-42EN low profile and full height Exhibit 4-4 adapters FC-42ES low profile and full height 18
Exhibit 4-5 adapters FC-41ES low profile and full height Exhibit 4-7 adapters FC-41XS low profile and full height Exhibit 4-6 adapters FC-42XS low profile and full height Exhibit 4-8 FC-21PS Adapter 19 ATTO Technology Inc.
Adapter board details Exhibit 4-9 Exhibit 4-10 FC-41EN FC-42EN 20
Exhibit 4-11 FC-44ES Exhibit 4-12 FC-42ES 21 ATTO Technology Inc.
Exhibit 4-13 FC-41ES Exhibit 4-14 FC-42XS 22
Exhibit 4-15 FC-41XS Exhibit 4-16 FC-21PS 23 ATTO Technology Inc.
5 Updating hardware flash Your Celerity FC host adapter was flashed before shipment, but the flash memory may need to be updated as new versions become available or if the factory-installed version becomes corrupt. Visit the ATTO website, www.attotech.com, to download the latest drivers and flash bundle. Hardware flash memory may need to be updated as new versions become available or if the factory-installed version becomes corrupt.
6 Troubleshooting This chapter contains solutions for the most common problems you might encounter. If you need additional assistance, please refer to the ATTO Technology website, www.attotech.com, or contact an authorized ATTO Technology representative. General suggestions • Check each cable connection on every device. • Verify all cables are in proper working condition. Loose or broken cables are often the cause of errors or problems.
If the devices connected to the Celerity FC host adapter are not accessible 1 Right-click My Computer. 2 Select Properties. 3 Select the Hardware tab. 4 Select Device Manager. • If the Celerity FC host adapter does not appear under the SCSI and RAID controllers, remove power from the PC, open the case, and check that the Celerity FC adapter is properly seated in the PCI slot. Replace the case and apply power.
Appendix A Standards and compliances The equipment described in this manual generates and uses radio frequency energy. The Technical Specification sheet for a particular Celerity FC host adapter list certifications for that model. FCC standards: radio and television interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Usage restrictions The use of optical instruments with this product will increase eye hazard. The multimode transceiver is a Class 1 laser product complying with IEC 825-1 and FDA-21 CFR 1040.11. To meet laser safety requirements, the transceiver shall be operated within the maximum ratings. The laser is non-OFC compliant as it is a Class 1 device. The optical ports of the modules must be terminated with an optical connector or with a dust plug.
Appendix B Accessories The following Fibre Channel accessories are available through ATTO Technology and authorized resellers. Contact an ATTO Technology authorized sales representative to order. Optical Cables CBL-FCFI-05x CBL-LCSC-003 CBL-LCSC-010 5 m. cable– Duplex 50 Micron Multi-mode FC/Optical 3 m. 50/125 optical cable (LC to SC) 10 m. 50/125 optical cable (LC to SC) A variety of iSCSI, Fibre Channel, SAS and SCSI products are also available from ATTO Technology.
Appendix C SCSI adapter selection guide Ultra 320 SCSI Product Features Max. transfer rate (MB/sec.) UL5D 640 UL5D LP 640 UL4D 640 UL4S 320 • • • • • • • • Number of SCSI Channels 2/2 0/2 2/2 1/1 Number of SCSI IDs supported 30 30 30 30 Large file transfers • • • • • Cable distances (m) 12.5 12.5 12.5 12.
Appendix D SAS adapter selection guide ATTO ExpressSAS RAID Adapters Product Features R348 R380 4 GB/sec. 4 GB/sec. x8 PCI Express • • Number of ports 8 8 4/8 user selectable 4/4 or 0/8 8/0 Max.
Appendix E Contact ATTO Technology, Inc. Customer service, sales information and technical support are available by phone Monday through Friday, Eastern Standard Time 8:00 a.m. to 8:00 p.m., or by e-mail and website 24-hours a day. ATTO Technology, Inc. 155 CrossPoint Parkway Amherst, New York 14068 (716) 691-1999 • voice (716) 691-9353 • fax http://www.attotech.com ATTO Technology can also be reached via e-mail at the following addresses: Sales Support: Technical Support: sls@attotech.