Instruction manual

18
Configuration Display page
Clicking on
Details
from the
Health and Status
Monitor
page gives you added information about
various aspects of the FastStream SC 5700 and
attached storage. Click on the arrow next to the
group you wish to view.
RAID groups: RAID group names, RAID status,
available Hot Spares, number of faulted drives,
RAID Level, number of partitions, Interleave and
total capacity of each RAID group.
Partitions: RAID group name, partition ID,
capacity and block size
Drives: Drive Configuration by port, including
drive size and status
Interfaces: Ethernet management port link
status and Fibre Channel port link, speed,
connection mode, Node Name and Port Name.
Phone home: E-mail messages
E-mail notification allows the FastStream SC
5700 to send an E-mail message to you, a network
administrator or other users when certain events
occur with the FastStream. Serious error
messages are sent immediately, while messages
for less serious errors are sent every 15 minutes.
Device transitions from online to offline
Critical and warning temperature conditions
Critical and warning voltage conditions
Power recycle/power failure conditions
Warning messages include:
• device down
• medium error
• abort command
Critical messages include hard errors.
Warning levels include:
All means warnings, critical events and
informational messages are sent.
Critical means only critical event E-mails are
sent.
Warning means only warnings and critical event
E-mails are sent.
None means no E-mails are sent.