Instruction manual

iv
CLI error messages
The following error messages may be returned by the Command line Interface
ERROR. Invalid Command. Type 'Help' for command list.
ERROR. Wrong/Missing Parameters
Usage: <usage string>
ERROR Invalid RAID Group state
ERROR Invalid Block Device index
ERROR Invalid RAID Member index
ERROR Maximum number of RAID Groups exceeded
ERROR Insufficient number of RAID Group members
ERROR
Block Device at specified index no longer available
ERROR Insufficient RAID Group members for RAID type
CLI summary
The following chart summarizes the Command
Line Interface commands, their defaults, and an
example of how to enter the commands.
Commands which have no default values have a
blank entry in that column of the table.
CAUTIONCAUTION
Do not use CLI unless you are directed to by an ATTO technician. Changing parameters may
cause loss of data and/or disruption to performance and reliability of the FastStream. The
ExpressNAV interface is the preferred method to operate and manage the FastStream SC 5700.
Refer to
Interface options
on page 29 for details.
Command Default Example
AutoMap automap
AutoResume
rebuild =enabled
erase=disabled
write pattern = disabled
set autoresume all enabled
BlockDevClean blockdevclean 30
BlockDevIdentify blockdevidentify Alpha
BlockDevIDStop blockdevidstop
BlockDevScan blockdevscan
BootFibreDelay 0 set bootfibredelay 15
BridgeModel get bridgemodel
BridgeName “ “ set bridgename Omega6
ClearEventLog cleareventlog
Date set date 03/03/2003
DefaultInterleave 128 set defaultinterleave 64
DeleteAllMaps deleteallmaps
DHCPFixedDelay 0 set dhcpfixeddelay 15
DisplayEventLog displayeventlog
DisplayEventLogFilter all all all set displayeventlogfilter gen info all
DriveTest drivetest begin
DriveTestConfig set drivetestconfig read
DriveTestList set drivetestlist all