Instruction manual

vii
ATTO Technology Inc. FastStream SC 5700 Installation and Operation Manual
CLI command explanations
Command Line Interface commands are listed
alphabetically with explanations of what they are
used for, their defaults and syntax.
CAUTIONCAUTION
Using CLI without contacting an ATTO
technician is not recommended because
changing parameters may cause loss of
data and/or disruption to performance and
reliability of the FastStream.
The ExpressNAV interface is the preferred
method to operate and manage the
FastStream SC 5700. Refer to
Interface
options
on page 29 for details.
AutoMap
Automap automatically maps a subset of target
devices visible to the firmware. All previous maps are
deleted.
AutoMap
AutoResume
Enables/disables the automatic continue feature for
interrupted rebuild, erase and write pattern operations at
startup. If AutoResume is enabled, all interrupted rebuild,
erase and write pattern operations are continued at
startup. Optional parameter GroupName specifies the
RAID group whose restart features are to be set. If no
GroupName is specified, all existing RAID groups are
affected.
set AutoResume [Rebuild | Erase | WritePattern | all]
[enabled | disabled] <GroupName>
BlockDevClean
Removes any ATTO configuration data from the block
device with the specified BlockDevID. BlockDevID is the
index of a block device provided by the
BlockDevSca
n
CLI command.
BlockDevClean [BlockDevID]
BlockDevIdentify
Causes the I/O LED of the drive to illuminate for one
minute if it is accessible through the FC port
.
CAUTIONCAUTION
The BlockDevIdentify command is
intended for diagnostic purposes only.
Executing this command may adversely
impact the performance and throughput
of the FastStream for the time that the
LED is illuminated.
ts port.
BlockDevIdentify <Groupname> [BlockDevID |
MemberIndex]
BlockDevIDStop
Turns off the IO LED of a previously identified disk drive.
BlockDevIDStop
BlockDevScan
Lists all currently connected physical drives along with
any potential RAID group association. Each block device
listed is assigned a unique index at the time of the scan to
identify drives for other CLI operations.
BlockDevScan
BootFibreDelay
Regulates the delay (in seconds) which the unit waits
after startup before enabling the Fibre Channel ports.
The value “0” constitutes no delay.
set BootFibreDelay [0 | 15 | 30 | 45 | 60 | 75]
get BootFibreDelay
BridgeModel
Reports model information about the FastStream.
get BridgeModel
BridgeName
Specifies a name assigned to the FastStream to identify
individual FastStream units. It is not the World Wide
Name. The string is alphanumeric, up to eight characters
long,.
Default: ““
set BridgeName [name]
get BridgeName
Voltage get voltage
WrapEventLog enabled set wrapeventlog disabled
zModem zmodem receive
Command Default Example