Instruction manual

ix
ATTO Technology Inc. FastStream SC 5700 Installation and Operation Manual
DumpConfiguration
Displays a units configuration.
DumpConfiguration
DumpEventLog
Dumps the contents of the entire event log to the current
CLI session without impact on the log itself (the log is not
cleared). No events are recorded until the command has
been completed.
DumpEventLog
EmailFromAddress
Configures the E-mail address that the FastStream uses to
talk to the E-mail server. Full E-mail address is a fully
qualified Internet E-mail address, not more than 128
characters.
set EmailFromAddress [full email address]
get EmailFromAddress
EmailNotify
Regulates E-mail notification.
Default: disabled.
set EmailNotify [enabled | disabled]
Requires a SaveConfiguration command
get EmailNotify
EmailNotifyAddress
Configures notification addresses using an index (a
number between 1 and 5, inclusive), the full E-mail
address of the recipient, a fully qualified Internet E-mail
address not more than 128 characters long, and a level.
Levels are
.....
None: no E-mails sent.
.....
Critical: critical event notification.
.....
Warning: warnings and critical event notification.
.....
All: all warnings, critical events
set EmailNotifyAddress [index] [full email address]
[warning level]
get EMailNotifyAddress <index | all>
EmailPassword
Configures the password used to authenticate the login to
the SMTP email server. The password must not be more
than 64 characters. A password is not required if the
email server does not require authentication.
set EmailPassword [password]
EmailServerAddress
Configures the address of the server that the FastStream
should contact in order to send E-mails.
Default: 0.0.0.0
set EmailServerAddress [IP address]
get EmailServerAddress
EmailUsername
Configures the user name used to authenticate the login
to the SMTP email server. The user name must not be
more than 128 characters. A user name is not required if
the email server does not require authentication.
set EmailUsername [Username]
get EmailUsername
EthernetSpeed
Sets/displays the current speed of the Ethernet
connection. Choices are
10, 100
, and
Auto
.
Default: auto
set EthernetSpeed [mp1] [ 10 | 100 | Auto ]
Requires a SaveConfiguration command
get EthernetSpeed [mp1]
EventLog
Regulates event logging. When enabled, the unit records
various system events to the event log.
Default: enabled
set EventLog [enabled | disabled]
get EventLog
EventLogFilter
Filters data from specific unit subsystems and levels when
event logging is enabled. The specific entries supported
are platform-dependent. For set commands, the final
parameter indicates whether or not events from the
specified subsystem and level are displayed.
Subsystem Levels
ECC INFO
ENET WARN
GEN CRIT
HTTP FAIL
NVRAM ALL
PERF
SCSI
NDMP
FC
ALL
set EventLogFilter [subsys | all] [event level | all] [all |
none]
get EventLogFilter [subsystem] [level]