Instruction manual

xii
Partition
Sets the specified partition to the specified capacity in
gigabytes (GB), megabytes (MB), or blocks. The specified
capacity must be smaller than the specified partition’s
current capacity. A new partition is created to acquire the
remainder of the original partition’s space.
VirtualDriveInfo displays characteristics and statistics
for all the available virtual drives or any available virtual
drive identified by its virtual drive ID.
Partition [GroupName] [PartIndex] [capacity] [GB | MB |
blocks]
PartitionDisplay
Lists all the partitions available in the specified RAID
Group. The partitions are listed in order of
contiguousness (as opposed to index order). GroupName
is the ASCII name of the RAID Group for which partitions
are displayed.
PartitionDisplay [GroupName]
PartitionMerge
Combines the specified contiguous partitions into one
partition. GroupName is the ASCII name of the RAID
Group containing the partitions to merge. PartIndex is
the index of a partition to merge, along with a number of
contiguous partitions to merge to that index. ‘All’
indicates that all partitions in the RAID Group are
merged into a single Virtual Disk. The RAID Group must
not be in a NEW state. None of the partitions to merge
may be mapped.
PartitionMerge [GroupName] [[[PartIndex] [2-128]] | All]
PartitionSplit
Divides the specified partition into one or more partitions
whose capacities are evenly distributed among the
capacity of the original partition. GroupName is the
ASCII name of the RAID Group containing the partition
to split. PartIndex is the index of the partition to split. The
partition to split cannot be mapped. The RAID Group
must not be in a NEW state.
PartitionSplit [GroupName] [PartIndex] [1-128]
Password
Specifies password for all non-serial sessions: Telnet, ftp
and FastStream browser-based user interface. You are
prompted for the current password, to type the new
password, and to confirm the new password. If local
echo
is enabled, password echoes all * characters. In verbose
mode only, CLI requests the password be re-typed. When
the password is all
0
s, Telnet and ftp do not validate the
password and MD5 authentication is disabled.
Passwords are case sensitive and can be 1-32 characters
long with no spaces.
Default: Password
set Password
Requires a SaveConfiguration command
Performance
Returns the performance data for the FC port you specify.
Data includes the average rate (MB per sec.) and number
of I/Os measured over the previous sampling period
where a sampling period is approximately one second.
Successful Read (08h, 28h) and Write (Oah, 2Ah)
commands are considered I/Os.Reported performance
may be affected by FC port availability and saturation
and overall system use.
get Performance <fp>
Ping
Sends an ICMP echo request to the specified host.
ping [mp1] [xxx.xxx.xxx.xxx] <count <size>>
RAIDCommandTimeout
Specifies in milliseconds the range of time the drives have
to respond. You must have created a RAID group to use
this command.
CAUTIONCAUTION
If you set this value too low, failures may
occur during normal operation.
Default: 30000
set RAIDCommandTimeout [100 - 3600000]
Requires a SaveConfiguration command
get RAIDCommandTimeout