Q-SERIES Optical ® QFOT 1310nm Series Broadcast Transmitter Installation & Operation Manual
Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Specifications subject to change without notice. Q-Series® is a registered trademark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-ATX product and company names in this manual are the property of their respective companies.
TABLE OF CONTENTS Page 1. PREFACE................................................................................................................................................... 1-1 2. OVERVIEW................................................................................................................................................. 2-1 3. FEATURES.................................................................................................................................................
This page left intentionally blank.
CHAPTER 1: PREFACE PREFACE 1. Preface This manual is designed for QFOT1310 series 1310nm broadcast transmitter along with a detailed description of product features, specifications, installation, adjustments and troubleshooting. To install this transmitter successfully and use it safely, users must read the manual carefully before installation, and perform their installation and adjustments according to this manual. Otherwise, some practices may lead to property damage or personal injury.
CHAPTER 1: PREFACE This page left intentionally blank.
CHAPTER 2: OVERVIEW OVERVIEW 2. Overview QFOT1310 is a 1310nm DFB laser transmitter delivering TV signals, digital TV signals, telephone voice signals and data signals over long distance fiber cable for CATV networks. The product utilizes a high performance cooled DFB laser as the light source, RF power digital automatic process technique, along with RF pre-distortion circuit. At the same time, a built-in microprocessor monitoring system automatically ensures the excellent performance of this transmitter.
CHAPTER 2: OVERVIEW This page left intentionally blank.
CHAPTER 3: FEATURES FEATURES 3. Features • High performance DFB laser with narrow spectrum and good linearity. • RF power digital automatic processing technology. • Excellent pre-distortion technology leading to the improved CTB, CSO and C/N. • Built-in microprocessor controlling laser and RF performance. • Front panel VFD screen displaying the transmitter status.
CHAPTER 3: FEATURES This page left intentionally blank.
CHAPTER 4: FUNCTIONAL DIAGRAM FUNCTIONAL DIAGRAM 4.
CHAPTER 4: FUNCTIONAL DIAGRAM This page left intentionally blank.
CHAPTER 5: SPECIFICATIONS SPECIFICATIONS 5. Specifications 5.1. Link Test Condition Test Condition: Test link consists of the QFOT1310 transmitter, 10 Km standard fiber, attenuator and standard optical receiver. Input RF channels are 59 PAL-D channels (equivalent to 77 NTSC channels). The optical receiver input power is -1 dBm. 5.2.
CHAPTER 5: SPECIFICATIONS 5.3.
CHAPTER 6: FUNCTION GUIDE FUNCTION GUIDE 6. Function Guide 6.1. Front Panel Guide 1 2 3 4 5 6 7 Front View 1 2 3 4 5 6 7 ATX Trademark LED Status Indicator: Green light: normal; Red light: warning. Check VFD message to troubleshoot problem. VFD Monitor: Displays each status parameter, product model, serial number and other information about this transmitter. UP Button: Scroll the VFD display UP, or increase setting value. Down Button: Scroll the VFD display DOWN, or decrease setting value.
CHAPTER 6: FUNCTION GUIDE 9 10 11 12 13 14 15 16 17 6.3. Optical Signal Output: Optical signal output port, SC/APC, or optional FC/APC connector. There are invisible laser emissions from Fiber output when laser is active! *It would be dangerous to point this port toward the human body especially eyes when equipment is energized! RS-232 Standard Network Management Port (optional): Use for connecting equipment with RS-232 port in network management server.
CHAPTER 7: INSTALLATION & MAINTENANCE HEADING 7. Installation & Adjustment 7.1. Opening the Cover 7.1.1. Inspect the package. If the packaging has been damaged, or shows signs of water damage, please contact the freight company or contact ATX. 7.1.2. After unpacking, check the equipment and accessories according to packing list. If there is any question, pleasecontact ATX. 7.1.3. If you think equipment has been damaged, please don’t turn on the power and avoid worse damage. Please contact ATX. 7.2.
CHAPTER 7: INSTALLATION & MAINTENANCE This page left intentionally blank.
CHAPTER 8: SNMP MANAGEMENT SNMP MANAGEMENT With the built-in SNMP interface board, QFOT1310-S can be viewed by SNMP software via the RJ-45 port at the rear panel. 8.1. IP Address 8.1.1. The QFOT1310-S transmitter default IP address for SNMP management is “192.168.1.20”. The Ethernet Interface hardware and TCP/IP features are as follows: 1) Interface Type: RJ45 2) Speed Rate: 10Mbit/s 3) Default IP Address: 192.168.1.20 4) Default Mask: 255.255.255.0 5) Default Gateway: 192.168.1.1 8.1.2.
CHAPTER 8: SNMP MANAGEMENT Commands Parameter Description Appendix Show / Show basic information Set Model “xxxxxxx” Model Set the Model View the Model When setting the model, the string must include quotation mark, and the max string length is 12 Set Location “xxxxxx” Location Set the location of the device View the location When setting the location string, the string must include quotation mark, and the max length is 12 Reboot / Reboot the device NOTE: • All commands will be uppercase,
CHAPTER 8: SNMP MANAGEMENT Q-Series® Optical – QFOT1310 Series Broadcast Transmitter – Installation & Operation Manual 8-3
CHAPTER 8: SNMP MANAGEMENT This page left intentionally blank.
CHAPTER 9: CLEANING & MAINTENANCE CLEANING & MAINTENANCE 9. Cleaning & Maintenance Each fiber connector can become contaminated by dust or dirt in the operation process, which can result in increased optical link loss, or a degraded carrier-to-noise ratio. If you find that the optical receiver power or RF output level of the optical receiver has declined, you should clean and maintain the fiber active connector.
CHAPTER 9: CLEANING & MAINTENANCE This page left intentionally blank.
CHAPTER 10: AFTER-SALE CUSTOMER SERVICE AFTER-SALE CUSTOMER SERVICE 10. After-sale Customer Service a) Our promises: One year free trouble fixing service and life-long customer service (1 year free guarantee time starts from the date indicated in products S/N attached on side of products). b) If the equipment fails, please contact ATX immediately. c) Don’t try to repair the problem without help from an ATX technician. d) NOTE: There are adhesive tape seals on both sides of the case.
CHAPTER 10: AFTER-SALE CUSTOMER SERVICE This page left intentionally blank.
CHAPTER 11: TROUBLESHOOTING TROUBLESHOOTING 11. Troubleshooting SYMPTOM FAULT ACTION No VFD or LED display after turning on the power. No input power or a problem with the internal switching power supply. Check input AC voltage to the power supply (AC90V~250V), if the voltage is normal, usually the cause is the internal switching power supply, contact ATX. After turning on power, VFD monitor and LED normal, but optical output power low. 1. Check jumper quality. 2.
CHAPTER 11: TROUBLESHOOTING This page left intentionally blank.
CHAPTER 12: SERVICE & SUPPORT SERVICE & SUPPORT 12. Service & Support 12.1. Contact ATX Networks Please contact ATX Technical Support for assistance with any ATX products. Please contact ATX Customer Service to obtain a valid RMA number for any ATX products that require service and are in or out-of-warranty before returning a failed module to the factory.
1-501 Clements Road West, Ajax, ON L1S 7H4 Canada Tel +1 (905) 428-6068 Toll Free +1 (800) 565-7488 Fax +1 (905) 427-1964 Toll Free Fax +1 (866) 427-1964 www.atxnetworks.com support@atxnetworks.com Printed in Canada Rev.