User manual

11
RS232 / RS485 / TCP/IP
TheM2hasRS232,RS485andTCP/IPportswhichallacceptthesamecommands.The
completecommandsettocontroltheM2isavailableintheM2commandsusermanual
whichisfreelydownloadableonwww.audac.eu
Wire up the system
Thewiringofthesystemmustbedoneaccordingtothefollowingrules,toguaranteea
properfunctioningofthesysteminallcircumstances.
1. Speakercableforamplifiedzoneoutputs:
Minimum 2 x 1.5 mm²
If distance > 15m: 2 x 2.5 mm²)
2. WallMountedInput&Controlunits:
DW3020/4020 UTP/FTP Cat6 cable or better
DW5065 UTP/FTP Cat6 cable or better
APM1xx UTP/FTP Cat6 cable or better
2. Musicsourcesandzoneoutputs:
Must be connected with high-quality audio cable and high-quality
connectors
3. Ethernetconnection:
UTP/FTP Cat5e cable or better