User manual

59
Limits
WhenmultipleAPM’sareconnectedononePIportusingabusstructure,amaximumof6
APM’scanbeconnectedtoonePIport,withamaximumcabledistanceof300meterfor
thetotalAPMbus.
PAGING CONNECTION LIMITS
-Maximum6APM’sononePIport
-AlwaysuseUTP/FTPCAT6(orbetter)cabling
-Maximum300metertotalbuslength
 In case a longer cable length is desirable, the maximum cable length can be
increased (up to 600 meter) by using CP43/45ARP Repeaters.
-AlwaysuseARJ03PjunctionboxeswithexternalpowersupplywhenmultipleAPM’s
areconnectedusingBusstructure.
-UseARJ03PwithexternalpowersupplywhenthecablelengthforoneAPMexceeds
133meter.
Bus
Max300meter
Configuration
Tomakethepagingsystemfunctioningaccordingtotherequirementsforyourspecific
project,theconfigurationprocedureshouldbefollowed.
Paging volume
Therequiredpagingvolumeforeveryoutputcanbedifferent,andshouldbeconfigured.
Thisconfigurationcanbedoneinthe‘PagingVolume’window,whichcanbefoundinthe
‘Settings’menuoverview.Thepagingvolumecanbesetinstepsof-1dB,startingby0
dB,goingto-.Whenthevolumeissetto0dB,announcementsforthecorresponding
outputswillbemadeonmaxiumvolume.
Besidesthepagingvolumeselectiona‘SwitchRelay’buttonisprovidedforeveryoutput.
Bymeansofthisbuttoncanbeselectedwhethertherelayforthecorrespondingoutput
shouldswitchautomaticallyincasepagingannouncementwillbemadeonthisoutput.
Thiscanbeusefulforbypassingexternal100Vvolumecontrollers,activatingemergency
lights,...