For the defined troubleshooting procedure, it is
possible, to switch oxygen sensor control off by
selecting display group 099 under "basic
setting" and switch it on again under "read
measuring value block".
After selecting display group 099 (either in
"basic setting" or "read measuring value
block"), it is possible to switch back and forth
between "basic setting" (function 04) and "read
measuring value block" (function 08) by
pressing buttons 4 or 8 on the VAG1551.
Once function 04 "basic setting" is exited,
oxygen sensor control is automatically switched
on again.
Test requirements:
Road test performed and DTC memory
erased.
Coolant temperature at least 80 C
Display group 4, display field 3