Service & Repair Manual

24-84
1 2 3 4
Display group 033: Oxygen sensor control before catalytic converter
Display
xx.x %
x.xxx volts
xx.x %
x.xxx V
Indicated
Oxygen sensor control
Bank1
Oxygen sensor voltage
bank 1
Oxygen sensor control
Bank2
Oxygen sensor voltage
bank 2
Functional
range
-25.0 to 25.0 %
0.100 to 1.000 V
-25.0 to 25.0 %
0.100 to 1.000 V
Specified
value
Value must fluctuate by
at least 2 % in the range
10.0 to 10.0 %
Value must fluctuate
approx. 0.3 V in the
range 0.100 to 1.000
volts
Value must fluctuate by
at least 2 % in the range
10.0 to 10.0 %
Value must fluctuate
approx. 0.3 V in the
range 0.100 to 1.000
volts
Notes
If specified value is not
obtained Page 24-85
If specified value is not
obtained Page 24-85