Service & Repair Manual

24-99
Rapid data transfer HELP
Select function XX
When indicated on display:
Note:
During basic setting, the Evaporative Emission (EVAP) canister purge
regulator valve (EVAP valve -N80-) is closed and the A/C compressor is
switched off
- Press buttons -0- and -4- to select "Initiate basic setting" and press -Q-
button to confirm input.
Basic Settin
g
Q
Input displa
y
g
roup number XXX
When indicated on display:
- Press buttons -0-, -3- and -4- to select "display group number 034" and
press -Q- button to confirm input.
System in Basic Setting 34
1 2 3 4
When indicated on display:
Note:
This process can take a few minutes.
- Use VAG1788/10 RPM adjuster to adjust engine speed to between
2800 and 3200 RPM.
- Continue test as soon as display field 2 indicates an exhaust
temperature of more than 380 C
Pa
g
e 28 of 63Ox
yg
en sensor control, checkin
g
11/23/2002htt
p
://127.0.0.1:8080/audi/servlet/Dis
p
la
y
?action=Goto&t
yp
e=re