Service & Repair Manual

24-108
Display fields
1 2 3 4
Display group 038: Diagnostic of oxygen sensor control system (Bank 2)
Display
xxx % x.xxx V xxx ms
---
Indicated
Engine
load
Oxygen sensor voltage
behind catalytic converter,
bank 2
Oxygen sensor correction
value between oxygen sensor
2 and oxygen sensor 2, bank
1
Diagnostic condition
Functional
range
12.0 to
100.0 %
0.100 to 1.000 V -800 to 800 ms
System OK
System not OK
Specified
value
12.0 to
26.0 %
0.100 to 1.000 V -800 to 800 ms System OK
Notes
If specified value is not
obtained: Evaluation
display field 2 Page 24-
109
If specified value is not
obtained Page 24-110
If "SYST not OK" is displayed:
Check Diagnostic Trouble Code
(DTC) memory Page 01-15
or continuation
Page 24-110
Note for display field 3:
The oxygen sensor control behind catalytic converter overrules the oxygen sensor control before catalytic converter. It
corrects slight changes in the mixture (i.e. toward rich or lean) due to the oxygen sensor before catalytic converter by holding
oxygen sensor control before catalytic converter at its higher or lower point for a specific time (dwell time). If this time is in the
positive range (i.e. 50 ms), mixture is shifted in the -enrich- direction. If this time is in the negative range (i.e. -50 ms), mixture
is shifted in the -lean- direction.
Pa
g
e 40 of 63Ox
yg
en sensor control, checkin
g
11/23/2002htt
p
://127.0.0.1:8080/audi/servlet/Dis
p
la
y
?action=Goto&t
yp
e=re
p
air&id=AUDI.B5.FU05.24.3