Service & Repair Manual

24-122
- Start engine.
Specification: approx. battery voltage,
possibly fluctuating
Notes:
At certain operating points, the ECM "pulses"
the Ground (GND) for oxygen sensor heating.
This means that the Ground (GND) is
constantly switched on and off at these points.
It is therefore possible that the voltage
displayed on the tester will fluctuate.
It is possible to observe the ECM switching
oxygen sensor heating on and off within the
function "read measuring value block", display
group numbers 041 and 042.
If there is no voltage:
- Connect multimeter for voltage measurement as follows:
Harness connector
Terminal
Measure to
1 (B+) Vehicle Ground (GND)
- Operate starter briefly.
Pa
g
e 57 of 63Ox
yg
en sensor control, checkin
g
11/23/2002htt