Service & Repair Manual

24-132
If LED does not light up:
- Check wire connection from terminal 1 to Fuel
Pump (FP) relay via fuse for open circuit.
Electrical Wiring Diagrams, Troubleshooting &
Component Locations binder
- Repair open circuit if necessary.
If LED lights up:
- Checking activation.
Checking activation
- Connect VAG1527B voltage tester to connector terminals 1 (B+) and 2.
- Initiate output DTM and activate Evaporative Emission (EVAP) canister
purge regulator valve -N80- Page 01-56 .
LED must blink.
Pa