Specifications

9
PHONO CARTRIDGE LOADING ADJUSTMENT
The phono cartridge load can be adjusted to suit your particular phono cartridge, using two pairs of
internal blue mini-switches.
The Jarrah mini-switches are factory set to a 47k load. Also, switch 1 is set in the on position. This is a
220pF capacitive setting and is usually required for RF suppression. It is not recommended that you turn
switch 1 off.
Disconnect the lead from the IEC socket on your Plinius Jarrah. Carefully remove the lid by undoing the
six cap screws. Locate the blue mini-switch banks to the rear of the circuit board. Adjust the settings of
the five individual switches (remember to do both channels) to give a loading required with reference to
the table below.
LOAD
REQUIRED
SWITCH NUMBER AND SETTING
1 2 3 4 5 6
LOAD
REQUIRED
SWITCH NUMBER AND SETTING
1 2 3 4 5 6
7.4
ON ON ON ON ON ON
29
ON ON ON ON ON
7.5
ON ON ON ON ON
30
ON ON ON ON
7.6
ON ON ON ON ON
31
ON ON ON ON
7.7
ON ON ON ON
32
ON ON ON
8.0
ON ON ON ON ON
41
ON ON ON ON
8.1
ON ON ON ON
43
ON ON ON
8.2
ON ON ON ON
45
ON ON ON
8.3
ON ON ON
47
ON ON
8.8
ON ON ON ON ON
76
ON ON ON ON
8.9
ON ON ON ON
82
ON ON ON
9.0
ON ON ON ON
90
ON ON ON
9.1
ON ON ON
100
ON ON
9.7
ON ON ON ON
320
ON ON ON
9.8
ON ON ON
470
ON ON
9.9
ON ON ON
1k
ON ON
10.0
ON ON
47k
ON
Now reassemble your Plinius Jarrah.