Specifications

ACTUATORS - INTERFACE - PRESENCE SENSOR KNX
ENERGY METER THREE PHASE WITH KNX INTERFACE
KNX-DMX INTERFACE
KNX PRESENCE SENSORS - INWALL OR SURFACE MOUNT
Active energy meter for three phase alternating with a backlit LCD display for displaying the values , an input for switching rates
between 2 rates and direct connection to 80 A. The values of instantaneous power, KW / KVA h and scored for rate 1 and 2,
are sent via the supplied KNX bus interface.
Interface between the KNX bus and the DMX512 bus. Combine items for building automation control devices dedicated to
enlightenment and special effects.One-way gateway that receives telegrams from the KNX bus and data bus to DMX512.



or fully automatic mode with the constant adjustment of brightness (dimming), the third is to slave mode, the fourth is a per-


passing reference to enlightenment.

ORDER CODE
ORDER CODE
ORDER CODE
TECHNICAL FEATURES
TECHNICAL FEATURES
TECHNICAL FEATURES
Energy meter three phase with KNX interface
KNX-DMX Interface
KNX Presence Sensors - Inwall
KNX Presence Sensors - Surface Mount
PM30A01KNX
IC00B01DMX
PD00C01KNX
PD00C02KNX
Main Features
Case 5 DIN 43880 DIN modules
Fixing 35 mm DIN rail EN 60715
Depth 70 mm
Reference standards:
Active energy - EN 50470-1-3
Reactive energy - output pulse EN 62053-23-31
Functionality
Electricity network connection 4-wires
Rates for active and reactive energy No. 2 T1 or T2
Supply
Power supply voltage 230 VAC
Voltage variation range 184 VAC ... 276 VAC
Nominal frequency 50 Hz
Power consumption (Max.) 8 -0.6 W VA
Overload
Permanent voltage Un, phase / phase 480 V
1 second: phase / phase 800 V
Permanent phase/N 276 V
1 second: phase/N 300 V
Permanent current Imax 80A
Momentary (0.5 s) 120A
Momentary (10 ms) 2400 A
Dimensions
107x75x31mm
Mounting
Width Mod 6. DIN
Operating Temperature
-5 ° C / 45 ° C
Control Elements
3 x 16 potentiometers, stepper positions
1 button (user), 2 LEDs (user)
1 button programming for KNX and LED
Dimensions:
98 x 50 mm H - Model Code PD00C01KNX
80 x 84.5 mm H - Model Code PD00C02KNX
Supply
24VDC to KNX / EIB-Bus Network
Detection area:
360 ° circular
Accuracy at 23 ± 1 ° C refer to the nominal values
Energy and power according to EN 50470-
3 active ± 1%
class 1 (B)
Energy and reactive power in accordance with EN
62053-23 class 2 ± 2%
Measuring inputs
Listing phase /N - direct
Current range (Ist ... Imax) direct connection
0,015... 80 A
Frequency: 50 Hz
Input waveform - sinusoidal
Minimum current for the measurement of
energy (Ist) 15 mA
S0 output according to EN 62053-31
Pulse output for active energy and reactive
Quantity impulse 500 imp / kWh
30 ± 2 ms pulse duration
Power required min. 5 ... .230% ± 5 VAC / Vdd
Optical interface
Calibration Front (precision control)
LED imp / kWh 1000
KNX Power
20 - 32V DC, 150 mW
Programming
Using the USB port
Supply
9-30V DC, 100mA, separated
Range (diameter) in meters:
Sitting 4.00 m
Movement away 10.0 m
Movement approaching 6.0 m
Degree of protection:
FM IP20 / Class II / EC
Ambient temperature: -25 ° C to +50 ° C
5756
Actuators
BUILDING
ACTUATORS - INTERFACE - PRESENCE SENSOR KNX
3 OUT DIMMER 1-10V
Dimmer used to control lighting circuits via a 1/10V connection, acting upon remote control dimmers or electronic ballasts.
Device is intended to be installed on DIN rail.
ORDER CODE
TECHNICAL FEATURES
3 OUT Dimmer 1-10V
DM03C02KNX
Dimensions
(H x W. X D) 86 x 72 x 66 mm
Mounting
Width 4 DIN modules
Connections
Bus line: 2 bus connection terminals, max section 0,8mm²
Outputs: 2 screw terminals for the relay contact and 2 for
the change
1-10v, up to section conductors. 2.5 mm²
Supply
From the KNX bus 21 .. 30 VDC SELV

3 power outputs with the following characteristics :
Incandescent 230V Max. 2300W
Halogen 2300W
Halogen lamps with magnetic transformer 1500 VA
1500W Halogen lamps with electronic transformer
1000W electronic ballast

3 outputs 50mA Max.
Control elements
1 button for programming ETS
1 button for setting the maximum value of brightness
Max. or min.
1 button for manual control of each output
Indicators
1 red LED for programming ETS
3 output status LEDs
ENERGY METER 80A MONOPHASE WITH KNX INTERFACE
Active energy meters for single phase AC with LCD display backlight for the display of values , an input for switching rates
between 2 and direct connection to 80A. The values of instantaneous power, KW / KVA h and score for tariff 1 and 2, are
sent via the supplied KNX bus interface.
ORDER CODE
TECHNICAL FEATURES
Energy Meter 80 A Monophase with KNX Interface
PM10A01KNX
Dimensions
Case - 3 modules DIN 43880
Fixing 35 mm DIN rail EN 60715
Depth 70 mm
Reference standards for active energy - EN 50470-1-3
reactive power - output pulse EN 62053-23-31
Functionality
Connection to single-phase 2-wires
Rates for active and reactive energy No. 2 T1 or T2
Supply
Power supply voltage 230 VAC
184 VAC voltage variation range ... 276 VAC
Nominal frequency 50 Hz
Power consumption (MaX.) 8 VA - 0.6 W
Overload
Permanent voltage Un 276 V / momentarily (1 s) 300 V
Permanent current Imax 80 A / momentary (10 ms) 2400 A
Accuracy at 23 ± 1 ° C refer to the nominal values
Energy and power according to EN 50470-3 active% ± 1 (B)
Energy and reactive power in accordance with EN 62053-23 ± 2%
Measuring inputs
Listing phase / W - direct
Current range (Ist ... IMaX) 0,025 direct connection ...
80 A
Frequency: 50 Hz
Input waveform - sinusoidal
Minimum current for the measurement of
energy (Ist) 25 mA
S0 output according to EN 62053-31
Pulse output for active energy and reactive
Quantity Pulse 1000 imp / kWh
30 ± 2 ms pulse duration
Power required min. 5 ... .230% ± 5 VAC / Vdd
Maximum Series Pulse ON (Max. 230 V AC / DC) 90 mA
Maximum Series Pulse OFF (leakage current Max. 230
VAC / DC) 1 µA
Optical Interface
Front Calibration (precision control) LED imp / kWh 1000