User manual

Siqura A-80
Page 30
Note: The factory-set IP address of the unit is in the 10.x.x.x range with a subnet mask of
255.0.0.0. Achieving initial communication with the unit requires that the network adapter of the
browsing PC is set to the factory default subnet of the A-80; for details, see Establishing a
Network Connection. Having made the internal web pages accessible in this way, you can use the
Network page to change the default network settings to the desired settings.
For IP address input to be valid, the unit's IP address:
must be within the 1.0.0.1 223.255.255.254 range
cannot start with 127 (reserved for loopback on local host)
Do not forget to Save and Reboot after changing IP settings.
Important: It is essential to set at least the IP address correctly and keep the value on record,
otherwise management of the unit will require special software. Note that the subnet mask is
also required.
9.3.1 Advanced Settings
Network page, Advanced Settings
Pressing the Advanced>> button on the Network page gives you access to the following settings.
Network
DHCP enable
Allows assigning of the IP address by a DHCP server instead of using static IP
addressing.
Ethernet mode
Transmission mode and speed.
Auto - Autonegotiation (default)
10 HDX - Half duplex, 10 Mbit.
10 FDX - Full duplex, 10 Mbit.
100 HDX - Half duplex, 100 Mbit.
100 FDX - Full duplex, 100 Mbit
IGMP unsolicited reports
enable
Enables sending of unsolicited messages, such as requests to join a multicast
group, for example, without having to wait for a query message from a
management PC, multicast router or switch.