Technical information

Operating Precautions for CPDW9X/NT-CDR-V85X, Y-GHS-MULTI-V800
TM
Customer Notification r20tu0003ed1812 34
No. a22
Unresolved static functions after two path inlining
Version Information
V3.5.1
Details
Using two path inlining on static functions causes that these functions can not be resolved during
linking stage. The problem is related to the amount and to the complexity of the static inlining
functions.
Workaround
A new compiler (PATCH to 3.5.1b4), which fixes this problem, can be downloaded from the NEC
WEB page(s) at http://www.renesas.eu/updates?id=443
No. a23
Automatically open editor on errors
Version Information
V3.5.1
Details
The function “automatically open editor on errors” doesn’t work using the compatibility mode
compiler.
Workaround
Use option “–c2000” to compile with the next generation compiler.
No. a24
GNUGREP generates application error
Version Information
V3.5.1
Details
The utility “gnugrep.exe” crashes when any filename on its command Line is more than 127
characters.
Workaround
None.