Specifications

33
48 Assign PF keys on the
control panel
You can assign functions to the PF
keys on the control panel as detailed in
the separate table.
49 Mic PF1 key
50 Mic PF2 key
51 Mic PF3 key
PF keys
52 Mic PF4 key
You can assign functions to the PF
keys on a multifunction mic as detailed
in the separate table.
53 Split frequency transfer Split
frequency
transfer
54 Permit to write #54 to target
VFOs
Transfer modes/frequencies between
compatible transceivers. Useful when
one is being used as a slave receiver.
TX inhibit 55 TX inhibit
Inhibits TX, which is useful if the
transceiver is to be used for RX only as
it prevents unintentional transmissions.
PC data rate 56 COM port communication
speed
Select 4800115200bps.
External
devices
57 DTS polarity
In data communications this switches
the logic for transmission. You should
match polarity to the external device
you are using.
TX inhibit 58 Busy lockout
You can select BSY lockout to inhibit
transmission when busy.
APO 59 APO (auto power off)
function
Power can be switched off
automatically in the absence of any
operations.
VOX source 60 Select input for VOX
Select either the mic or the data input
for VOX activation. Standby wiring may
not be required provided that the
method used is compatible with data
communications. (Be careful to ensure
correct TX delay.)