User manual
14
E
Some installation regulations require redundant
zones for emergency announcements.
With the MX-AMP 60 and MX-AMP 120 you can
select a special speaker zone for emergency
signals or announcements. In this case the
MUSIK/SPEECH-Zone is mute and the signal is put
on the SPEECH/ONLY-Zone.
Disjoined Announcement Zones
The amplifier provides two different Loudspeaker
zones.
! The Music/Speech - Output gives an output at
all times reproducing any signal input into the
amplifier.
! The Speech Only - Output will only reproduce
a signal during priority condition. This means
that only the 'Ding Dong' chime and the signal
from one of these microphone inputs will be
presented to this output.
100V Speaker Output 8ohm Speaker Output
14
EN
This output allows connection of standard low
impedance loudspeakers. The minimum load
impedance must be 8ohm. When two or more
loudspeakers are connected, ensure that they are
wired in such a way, that the load impedance is
between 8ohm and 16ohm.
Device Functions
- Rear side -
ic audio
SPEECH ONLY
MUSIC / SPEECH
Normal Priorität
SPEECH ONLY
MUSIC / SPEECH
D
C
24
V
N
D
G
PRIO
R
I
Y
T
+
-
I
PUTN
C
H M
E
I
CHIME
ON OFF
X