Specifications
15
5. The next screen lists the zone group setting, along with three PX-603 rooms available for
each zone. The default setting for all PX-603 rooms is N (no), meaning that no PX-603
rooms assigned to the zone group will come on when the ALL-ON command is activated.
For zones with no PX-603 rooms, no change is required in this screen. For zones contain-
ing PX-603 rooms, select Y (yes) or N (no) to include or exempt PX-603 rooms as part of
the ALL-ON group.
6. When all room assignments have been made, highlight EXIT and press ENTER.
Paging Setup
The Page/Doorbell Module (sold separately), used with a PX-600 system, will generate door-
bell chimes and/or route paging audio through selected zones at selected volumes. Paging is
selected by zone. Paging will occur in PX-603 rooms attached to PX-600 main rooms chosen
for paging in the same manner paging occurs in the main room (i.e. page when zone off, page
when zone on). PX-603 rooms page at their turn-on volume (see below). No additional
paging screens are in the programming menu. See the PX-600 Installation Manual for specific
instructions to program paging.
Multi PX-600 Systems
Up to six PX-600s may be connected together to operate as one system for expanded flexibility
and independent control, and up to six PX-603s can be connected to each PX-600. The only
programming difference for multi-systems is the ALL-ON grouping as described above. These
changes will be found in the MULTI-SETUP menus.
Note
All PX-600s in the system must have the same software version, which must be version 2.0 or
above. All KPS keypads in the system must have software version 1.6 or above.
Setting Turn-on Volume
Turn-on volume for a PX-603 room is set at the KPS or KP3 keypad for that room. Start with
the room off. Press the ON button, then adjust the volume level up or down to the desired
turn-on volume. Press the ON button again to turn the room off, then within five seconds
press the volume up and down arrows simultaneously (the MUTE command). The ON LED
will blink three times to acknowledge that the new turn-on volume has been accepted. The
PX-603 is shipped with factory default values set at reasonable listening levels.