Specifications

19
System 1 Line Diagram
The following diagram shows how two PX-603 rooms are strapped together when they are
assigned to the same zone. This particular configuration is set up for the system in Block
Diagram One, but is representative of any application in which multiple PX-603 rooms are part
of a zone. The output from Zone 4 is connected to Audio Input one, and the corresponding
DIP switches are set to reflect Zone 4, Room 1, System 0 (DIP switches 3 and 4 in the up
position). The Zone Output of Zone 5, which has two PX-603 rooms assigned, is connected to
Audio Input 2, and a jumper (14 mm staple variety or short RCA cable) is inserted from the
loop-thru of Input 2 to Audio Input 3. DIP switch sets are addressed accordingly: set two is
configured for Zone 5, Room 1, System 0 (switches 1, 3, and 4 up) and set three is configured
for Zone 5, Room 2, System 0 (switches 1, 3, and 8 up).
Diagram 3
AUDIO INPUTS SPEAKER OUTPUTSEQ POWERKEYPADS ROOM CONFIGURATIONS
R
L
R
L
120V
~
60Hz 480 WATTS
SERIAL NUMBER
MODEL:
PX-
603
MANUFACTURED IN THE USA
AUDIOACCESS, HAYWARD, CA
1
23
123
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE. DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
ZONE
ROOM
SYSTEM
ROOM
ZONE
ROOM
SYSTEM
ROOM
ZONE
ROOM
SYSTEM
ROOM
KP-3
KPS
3
RED
GRN
YEL
BLK
+
+
21
123
1
RL
2
RL
3
RL
1
2
3
12345678 12345678 12345678
ON
ON
ON
ZONE OUTPUTS
123456
AUDIO INPUTS / LOOP-THRU
TUNER CD
R
L
R
R
L
L
R
IR OUTPUTS
TUNER CD TAPE AUX VIDEO ALL
SWITCHED
L
SERIAL NUMBER
KEYPAD
FUSE
PREAMP OUTPUTS
123456
PAGE
(MONO)
TAPE AUX VIDEO
ZONE TRIGGERS
1
2
34
56
V
IN
AVIS:
RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:
TO
REDUCE THE RISK OF
FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS
EQUIPMENT TO RAIN
OR MOISTURE
MODEL:
PX-
600
MANUFACTURED IN THE
USA BY AUDIOACCESS
HAYWARD, CA
(200W MAX) 120V
~
60Hz 240 WATTS
CAUTION:
FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE ONLY WITH
2A 250V SLOW BLOW FUSE
ATTENTION:
UN FUSIBLE DE RECHANGE
DE MEME TYPE DE 2A 250 SLOW BLOW
ZONE 6
TAPE
OUT
TRIGGERS
IR
IN OUT IN OUT PAGE
RED
GRN
YEL
BLK
1.5A
SLOW BLOW
ROOM CONFIGURATIONS
ZONE
ROOM
SYSTEM
ROOM
ZONE
ROOM
SYSTEM
ROOM
ZONE
ROOM
SYSTEM
ROOM
321
12345678 12345678 12345678
ON
ON
ON
System 2 Block Diagram
System Two shows the use of two PX-603s to add two additional rooms in each of three zones.
As in System 1, Zones 1, 2, and 3 are single rooms with independent source selection and
volume control as each serves a separate function within the home.
Zone 4, the Master Suite, contains three rooms: the bedroom, bath and sitting room. The
bedroom is the PX-600 room with full source control via a KPS and RT-A remote. The bath
and sitting rooms require only room on/off and volume control as available with the KP3
keypad located in each room.
Zone 5 contains the Kitchen, Laundry Room and Breakfast Room. While these rooms can be
closed off from each other with doors, the homeowners have decided that they are all likely to
be in use at the same time, especially on weekends, so playing a single source in all of them at
once makes the most sense.
The Foyer and Living Room of Zone 6 are open, adjoining areas with a shared airspace. They
are mainly used in social situations and require very low music levels; however, the homeowners
would like a KPS in the Living Room. The Den is the main room of this zone, containing the
system control units and all source equipment.