User`s manual

SIP User's Manual 180 Document #: LTRT-83303
Mediant 1000 & Mediant 600
Parameter Description
Message Waiting Indication (MWI) Parameters
Note: MWI is applicable only to Mediant 1000.
Enable MWI
[EnableMWI]
Enables Message Waiting Indication (MWI).
[0] Disable = Disabled (default).
[1] Enable = MWI service is enabled.
Notes:
This parameter is applicable only to FXS interfaces.
The device supports only the receipt of SIP MWI NOTIFY messages
(the device doesn't generate these messages).
For detailed information on MWI, refer to "Message Waiting Indication"
on page 440.
MWI Analog Lamp
[MWIAnalogLamp]
Enables visual display of MWI.
[0] Disable = Disable (default).
[1] Enable = Enables visual Message Waiting Indication by supplying
line voltage of approximately 100 VDC to activate the phone's lamp.
Note: This parameter is applicable only for FXS interfaces.
MWI Display
[MWIDisplay]
Determines whether MWI information is sent to the phone display.
[0] Disable = MWI information isn't sent to display (default).
[1] Enable = The device generates an MWI message (determined by
the parameter CallerIDType), which is displayed on the MWI display.
Note: This parameter is applicable only to FXS interfaces.
Subscribe to MWI
[EnableMWISubscriptio
n]
Enables subscription to an MWI server.
[0] No = Disables MWI subscription (default).
[1] Yes = Enables subscription to MWI (to MWIServerIP address).
Note: Use the parameter SubscriptionMode (described in Proxy &
Registration Parameters on page 146) to determine whether the device
subscribes per endpoint or per the entire device.
MWI Server IP Address
[MWIServerIP]
MWI server's IP address. If provided, the device subscribes to this IP
address.
The MWI server address can be configured as a numerical IP address or
as a domain name. If not configured, the Proxy IP address is used instead.
MWI Server Transport
Type
[MWIServerTransportTy
pe]
Determines the transport layer used for outgoing SIP dialogs initiated by
the device to the MWI Server.
[-1] Not Configured (default)
[0] UDP
[1] TCP
[2] TLS
Note: When set to ‘Not Configured’, the value of the parameter
SIPTransportType is used.
MWI Subscribe
Expiration Time
[MWIExpirationTime]
The MWI subscription expiration time in seconds.
The default is 7200 seconds. The range is 10 to 72000.