3.5.1.3.3 Saving Configuration
The 'Maintenance Actions' page allows you to save (burn) the current parameter
configuration (including loaded auxiliary files) to the device's non-volatile memory (i.e.,
flash). The parameter modifications that you make throughout the Web interface's pages
are temporarily saved (to the volatile memory - RAM) when you click the Submit button on
these pages. Parameter settings that are only saved to the device's RAM revert to their
previous settings after a hardware/software reset (or power failure). Therefore, to ensure
that your configuration changes are retained, you must save them to the device's flash
memory using the burn option described below.
¾ To save the changes to the non-volatile flash memory , take these
2 steps:
1. Open the 'Maintenance Actions' page (refer to ''Maintenance Actions'' on page 262).
2. Under the 'Save Configuration' group, click the BURN button; a confirmation message
appears when the configuration successfully saves.
Notes:
Saving configuration to the non-volatile memory may disrupt traffic on the
device. To avoid this, disable all new traffic before saving, by performing
a graceful lock (refer to ''Locking and Unlocking the Device'' on page
264).
Throughout the Web interface, parameters preceded by the lightning
symbol are not applied on-the-fly to the device and require that you reset
the device (refer to ''Resetting the Device'' on page 262) for them to take
effect.