User`s manual

Table Of Contents
Mediant 2000 & TP-1610 & TP-260
SIP User's Manual 388 Document #: LTRT-68805
I.1.4 Component: SS7#0
The source varbind text for all alarms under this component is
Board#<n>/SS7#0/SS7Link#<m> where n is the slot number and m is the link number.
Table I-11: acSS7LinkStateChangeAlarm Trap
Alarm:
acSS7LinkStateChangeAlarm
OID:
1.3.6.1.4.1.5003.9.10.1.21.2.0.19
Default Severity
Major
Event Type:
communicationsAlarm
Probable Cause:
Other
Alarm Text:
*** SS7 *** Link %i is %s $s
Status Changes:
Condition:
Operational state of the SS7 link becomes ‘BUSY’.
Alarm status: Major
<text> value: %i - <Link number>
%s - <state name>: { "OFFLINE", "BUSY", "INSERVICE"}
%s – If link has MTP3 layer, then this string equals:
(SP %i linkset %i slc %i)
Where:
%i - <SP number>
%i - <Link-Set number>
%i - <SLC number>
Otherwise there is NO additional text.
Additional
Info1 varbind
BUSY
Condition:
Operational state of the link becomes ‘IN-SERVICE’ or ‘OFFLINE’.
Alarm status: Cleared
Corrective Action:
For full details refer to the SS7 MTP2 and MTP3 relevant standards.