User manual

Assigning an EDID
8
Section 4.5
5. Press the EDID capture button (see
) on the WP-101 and connect the adapter to the mains electricity.
Figure 7).
The EDID status LED flashes slowly several times. The new EDID is
captured when the LED stops flashing and lights solid.
6. Unplug the power adapter from the mains and disconnect it from the WP-101.
7. Replace the faceplate and secure the four screws removed in
Step 1
5.2 Setting a Preconfigured EDID
.
Figure 7 and Table 3 define the location of the PCB features used when setting the
EDID manually.
Figure 7: WP-101 PCB Assembly Front View with Face Plate Removed
Table 3: WP-101 PCB Assembly Features
# Feature Function
1 Equalization Trimmer Using a small, flat screwdriver, turn to adjust the signal equalization (see
Section 5.3
2
)
16 Position Rotary Switch Using a small, flat screwdriver, turn to select the EDID resolution and refresh
rate (see
Table 4)
3 EDID Capture Button Press to capture the EDID
4 EDID Status LED Flashes green slowly when capturing a valid display EDID; lights solid when
EDID has been successfully captured; flashes rapidly when setting a
preconfigured EDID
To set a preconfigured EDID:
1. Using a Philips screwdriver, from the rear of the unit, remove the four screws
holding the face plate panel to the rear PCB assembly.
2. Using a small, flat screwdriver, turn the rotary switch located on the PCB
assembly (see
Figure 7) to the required position as defined in Table 4.