User manual

Assigning an EDID
9
9
3. Connect the 12V DC power adapter to WP-101 (see Section 4.5
4. Press the EDID CAPTURE button (see
) and to the
mains electricity.
Figure 7).
The EDID status LED flashes green rapidly several times. The new EDID is
captured when the LED stops flashing and lights solid.
5. Unplug the power adapter from the mains and disconnect it from the WP-101.
6. Replace the faceplate and secure the four screws removed in
Step 1
Table 4: WP-101 Rotary Switch EDID Resolution Settings
.
Rotary
Switch
Position
Resolution Refresh
Rate
Rotary
Switch
Position
Resolution Refresh
Rate
0 (Default) 1024x768 60Hz 8 1440x900 60Hz
1 800x600 60Hz 9 1440x1050 60Hz
2 1024x768 60Hz A 1600x1200 60Hz
3 1152x864 75Hz B 1680x1050 60Hz
4 1280x720 60Hz C 1920x1080 60Hz
5 1280x800 60Hz D 1920x1200 60Hz
6 1024x1024 60Hz E For future use
7 1360x768 60Hz F For future use
5.3 Setting the Equalization
To adjust the signal equalization:
1. Using a Philips screwdriver, from the rear of the unit, remove the four screws
holding the face plate panel to the rear PCB assembly.
2. Using a small, flat screwdriver, turn the trimmer located on the PCB assembly
(see
Figure 7).
3. Connect the 12V DC power adapter to WP-101 (see
Section 4.5
4. Replace the faceplate and secure the four screws removed in
) and to the
mains electricity.
Step 1
.