User`s manual

55
12.2 Set Digital Output Mode
To adjust the output format of the digital outputs of the ART G2 press
key stop / set long twice. Use keys back / pause and play to select the
output format.
LowBit Mode Use the LowBit mode if the ART G2 is connected to a unit
that does not support the Audionet HighBit Interface.
HighBit Mode Use the HighBit mode only if you connect the ART G2
to a unit that supports the Audionet HighBit Interface,
like Audionet MAP V2.0 or Audionet MAP 1.
disabled All digital outputs are disabled. Select this option if you
do not use any of the digital outputs of the ART G2.
Important
ยท If you do not need any of the digital outputs do not use any jumpers
to short-circuit the digital outputs. Instead, select disabled for op-
tion Set Digital Output Mode to switch off all digital outputs.
Please refer to the following tables to determine which digital output
format at which sample rate and resolution is available at the digital audio
outputs. The decision whether to use the HighBit or the LowBit mode
depends on the kind of digital receiver unit your ART G2 is connected to
(refer to section 'Digital output format' on page 14).
Digital
Output
Mode
DATA
LINK 9
OUT 1 10
SPDIF
OUT 2 11
SPDIF
OUT 3 12
AES/EBU
OUT 4 15
optical
LowBit
Mode
44.1kHz / 16bit
Stereo
PCM
44.1kHz / 16bit
Stereo
PCM
44.1kHz / 16bit
Stereo
PCM
44.1kHz / 16bit
Stereo
PCM
44.1kHz / 16bit
Stereo
PCM
HighBit
Mode
192kHz / 24bit
Stereo Upsampling
Audionet High Bit
Mode
192kHz / 24bit
Stereo Upsampling
Audionet High Bit Mode
96kHz / 24bit
Stereo
Downsampling
PCM
44.1kHz / 16bit
Stereo
PCM
disabled no signal no signal no signal no signal no signal