Installation manual
8.3.8 Grounding the SMC
A grounding lug can be found at the bottom of the
SMC. An appropriate ground wire should be secured
between the grounding lug and an earth ground point,
such as a grounding rod or a grounded metallic water
pipe. Insert the ground wire into the lug and tighten
with a screwdriver. A minimum No. 10, solid conductor,
bare copper wire is recommended to ground the unit.
8.4 Structured Cabling
(Pre-Wire)
A Category 5 or 5e compliant installation involves more
than simply the use of Category 5 or 5e cable. For full
compliance, jacks and cable must meet EIA/TIA 568-A
electrical and mechanical specifications and transmis-
sion requirements. A Category compliant installation
will minimize the attenuation, near-end crosstalk
(NEXT), return loss and signal-degrading factors that
can greatly affect a system’s transmission ability.
Category compliance can be altered by the method of
installation. Improper cable routing and support, as
well as kinking, stretching, and crimping all negatively
affect the cabling performance. Proper cable installa-
tion is critical to system integrity.
8-6
For more information call your Leviton representative or the Leviton Technical Hotline at 800-722-2082
© Copyright 2001 Leviton Manufacturing Co., Inc.
Installation Manual
Nut Nut
Plug Bushing Bushing
Remove large conduit knockouts in top of Structured
Media Center and install bushings for cable protection.
Mount the unit between studs. Install a ground wire from
the green ground screw to earth ground.
Prepare Structured Media Center
Ground
Wire
Structured Media Center Installation and Wiring Instructions
Nut
Nut
8
PRE-WIRE
Installation,
Labeling and
Documentation
Pre-Wire
Installation
TIP
RING
ACCESSORY
GROUND
PAIR1
PAIR 2
GREEN
BLACK
YELLOW
R
E
D
PAIR 1
PAIR 2
PAIR 3
TIP
RING
TIP
RING
TIP
RING
BASE COLOR
BAND COLOR
TIP
RING
PAIR 4
GREEN
RED
BLACK
YELLOW
Category 5 or 5e Cable (New) Quad Wire (Old)