Owner's Manual

24
ACO platform features
Beside the unique DSP sound e󰀨ects the DSP.3S
provides a bunch of new system and DSP features.
In the DCM menu of the DSP PC-Tool software in-
dividual settings can be made for several of these
system features.
Turn On & O󰀨 Delay
This function allows to determine the delay time with
which the DSP is switched on and o󰀨. The factory
setting is 0.2 seconds. The delay time should only
be modied if there are e.g. noises while switching
on / o󰀨 the signal processor.
URC Setup Switch Conguration
The ACO provides ten internal memory locations for
sound setups instead of the common two.
By using an optional URC remote control or the Con
-
trol pushbutton it is possible to toggle between two
of the ten memory locations. These two memory lo
-
cations can be determined in the “URC Setup Switch
Conguration”. The memory locations one and two
are preassigned by default. To switch between all
internal memory locations, the optionally available
remote controls DIRECTOR and CONDUCTOR or
the HELIX WIFI CONTROL are / is recommended.
Remote Output Conguration
This function controls if the remote output (which
switches on and o󰀨 the connected ampliers) will
be temporarily deactivated during a sound setup
switch. This function is activated (ON) by default.
ADEP.3 Conguration
If the DSP.3S is connected to an OEM radio via the
highlevel inputs it may happen that the ADEP.3 cir-
cuit has to be adapted to the diagnostic mode of the
radio if the latter is equipped with a so-called “class
SB” output stage”.
The ADEP.3 circuit should be adjusted if there are
e.g. distortions in the upper volume range.
The compatibility mode is disabled by default.