Hooksett Fire –Rescue Department
Specifications for Stainless Steel Pumper Tanker Bid # 11-05
20
Bidder
Complies
Yes No
PUMP SERVICE ACCESS REQUIREMENTS
It is the opinion that service access to the pump, valves, gauges and controls are of the utmost
importance. Special consideration shall be taken when evaluating the pump module design of the
offered. Pump panels that offer little to no access without the use of tools shall not be considered
compliant with this requirement.
PUMP CONTROL PANELS
All pump controls and gauges shall be located at the left (street) side of the apparatus and properly
identified. The layout of the pump control panel shall be ergonomically efficient and systematically
organized. The pump operator's panel shall be removable in two (2) main sections for ease of
maintenance. The pump and gauge panels shall be constructed of 12-gauge stainless steel. The
gauge panel shall contain a panel for mounting of all instruments, engine monitoring system, and
pressure control system.
The gauge panel shall be a double panel door design to protect in the enclosed door all gauge tubing,
switch, and control wiring. The gauge panel exterior shall be made of 12-gauge stainless steel. The
inner pan shall bolt onto the stainless exterior panel. There shall be an access panel in the inner
panel easily removable for control or gauge service or replacement.
The gauge panel door shall be designed as an opening pump house service door on the street (left)
side of the pump house. This gauge panel door shall provide an opening minimum size of 41 inches
wide by 14 inches in height.
The lower section of the panel shall contain all inlets, outlets, and drains. All push-pull valve controls
shall have quarter turn locking control rods with chrome plated zinc tee handles. Guides for the push-
pull control rods shall be chrome plated zinc castings securely mounted to the pump panel. Push-pull
valve controls shall be capable of locking in any position. The control rods shall pull straight out of the
panel and shall be equipped with universal joints to eliminate binding.
There shall be an opening pump house service door on the curb (right) side of the pump house. This
door shall provide an opening minimum size of 41 inches wide by 14 inches in height.
All stainless panels used in the construction of the pump house shall have a brushed finish.
PUMP PANEL IDENTIFICATION TAGS
The identification tag for each valve shall be recessed in the face of the control handle. All discharges
shall have color-coded plastic identification tags, with each discharge having its own unique color.
Color-coding shall include the labeling of the outlet and the drain for each corresponding discharge.
CONTROLS AND GAUGES
The following shall be provided on the pump and gauge panels in a neat and orderly fashion. The
gauge panel shall include the following:
ENFO-III ENGINE MESSAGE CENTER
Class1 ENFO III Engine Information Display
Class 1 Pressure Governor (captain)