Specifications

Hooksett Fire –Rescue Department
Specifications for Stainless Steel Pumper Tanker Bid # 11-05
22
Bidder
Complies
Yes No
PUMP PANEL LIGHTING
The pump operator's panel shall be supplied with a LED light system. LED strip lights with a stainless
steel hood shall be mounted across the top of the pump panel gauges and controls on each side.
All pump module lighting shall illuminate automatically when the parking brake is engaged.
DRAIN DISCHARGES
The 3/4 inch drain valves shall be equipped with 90-degree fittings with 3/4" I.D. tubing to direct the
discharge water toward the ground.
AIR HORN ACTIVATION SWITCH
A switch shall be located on the pump panel to activate the chassis air horn. The switch shall be a
momentary pushbutton weatherproof type switch. The switch shall be supplied with the proper
identification label.
RADIO COMPARTMENT
A fully enclosed polished stainless steel radio compartment shall be furnished and installed, location to
be decided at the pre-construction meeting.
The radio compartment shall be construct of 12ga. stainless steel. The compartment shall have a
hinged door with gasket and a single lift and turn type latch.
WATER TANK LEVEL GAUGE
The apparatus shall be equipped with a Class 1 "Inteli-Tank" Tank Level Gauge for indicating water
level.
HIGH VISIBILITY WATER TANK LEVEL INDICATORS - ADDITIONAL
There shall be in addition to the Class 1 water tank level gauge on the pump operator's panel and in
the cab, a Whelen PSTANK LED high visibility water level indicator supplied one (1) on each side of
the pump module on the dunnage area sides. As well as one located at the rear of the apparatus
body.
PUMP MANUFACTURER AND MODEL
The pump shall be a Hale Q-FLO Plus model midship pump.
NO EXCEPTIONS
PUMP RATING AND TEST REQUIREMENTS
The pump shall be of a size and design to mount on the chassis rails of commercial truck chassis, and
have the capacity of 1250 gallons per minute (U.S. GPM), NFPA1901 rated performance.
AIR PRIMER
The pump shall be furnished with an air driven venturi priming system. The system shall be plumbed
to the chassis air. A switch to control the air primer shall be provided on the pump operator's panel.