Specifications
Hooksett Fire –Rescue Department
Specifications for Stainless Steel Pumper Tanker Bid # 11-05
5
Bidder
Complies
Yes No
sound and the outward appearance remains in a “like new” condition, with minimal
maintenance and upkeep, throughout the service life of the apparatus. Aluminum apparatus
bodies and differing construction designs will be reviewed and considered only if the builder /
manufacturer will meet the same “Body Structural Warranty” requirements specified in this bid
document. Regardless of materials used or design, the entire body design shall be of a bolted
design to allow for ease of removal for repair or replacement, without cutting welds.
ROAD TEST CERTIFICATION
A road test shall be conducted with the finished apparatus fully loaded. During this time, the
apparatus shall not show loss of power and/or overheating. The transmission driveshaft or
shafts and rear axle shall run free from abnormal vibration or noise throughout the operating
range of the apparatus. The apparatus, when loaded, shall have not less than 25% or more
than 45% of the weight on the front axle and not less than 55% or more than 75% on the rear
axle.
A. The apparatus must be capable of accelerating to 35 mph from a standing start within 25
seconds on a level concrete highway without exceeding the maximum governed RPM of the
engine.
B. The apparatus must be capable of accelerating from a steady speed of 15 mph to a true
speed of 35 mph within 30 seconds. This shall be accomplished without moving the gear
selector.
C. The fully loaded apparatus shall be capable of obtaining a speed of 50 to 55 mph on a
level concrete highway.
D. The manufacturer shall furnish copies of the engine installation approvals signed by the
appropriate engine company upon delivery of the chassis to the Fire Department. No
exceptions will be permitted to this section of the document.
E. The manufacturer shall furnish copies of the transmission approval signed by the
transmission manufacturer upon delivery of the chassis to the Fire Department. No
exceptions will be permitted to this section of the document.
F. The manufacturer shall furnish copies of the front and rear axle approvals upon delivery of
the chassis to the Fire Department. No exceptions will be permitted to this section of the
document.
ROAD TEST FAILURE
In the event the apparatus fails to meet the test requirements of these specifications on the
first trials, second trials may be made at the option of the manufacturer within thirty (30) days
of the first trials. Such trials shall be final and conclusive and failure to comply with changes
as the Hooksett Fire Department may consider necessary to conform to any clause of the
specifications within thirty (30) days after notice is given to the manufacturer of such changes,
shall also be cause for rejection of the apparatus. Permission to keep or store the apparatus
in any building owned or occupied by the Hooksett Fire Department, or its use by the Fire
Department during the above specified period with permission of the manufacturer, shall not
constitute acceptance.