Specifications
Proposal Number PSDF #P09-0004
WEATHER RESISTANT TUBING
The AC wiring in the apparatus body shall be installed in seal tite weather resistant conduit.
FORWARD FACING BROW LIGHT
One (1) brow light shall be provided and mounted centered on the leading edge of the cab roof facing
forward.
There shall be One (1) Fire Research Focus FCA800 Series roof mount lamp head(s) provided. The
mounting bracket shall attach to the light head chosen for the mounting position. Wiring shall exit from a
weatherproof strain relief on the lamp head.
The lamp head shall have one (1) quartz halogen 750 watt 120 volt bulb. The bulb will draw 6.3 amps and
generate 19,600 lumens. The bulb shall be accessible through the front. The lamp head shall direct 50
percent of the light onto the action area while providing 50 percent to illuminate the working area. The lamp
head shall incorporate heat-dissipating fins and be no more than 5" deep by 3 3/8" high by 10" wide. Lamp
head and mounting arm shall be powder coated white. The floodlight shall be UL listed as a scene light for
fire service use.
The brow light shall have a white housing
One (1) 12-volt, switch shall be wired through 120-volt relay and shall be located in the cab switch panel for
the apparatus body quartz light(s) as selected.
FRONT BODY QUARTZ LIGHTS
The following light shall be provided mounted on the left and right front corners of the body:
Fire Research Focus model FCA100-M15 lamp head shall be provided. The lamp head mounting arm shall
terminate in 3/4" NPT threads. Wiring shall extend from the lamp head mounting arm bottom.
The lamp head shall have one (1) quartz halogen 1500 watt 240 volt bulb. The bulb will draw 6.25 amps and
generate 35,000 lumens. The bulb shall be accessible through the front. The lamp head shall direct 50
percent of the light onto the action area while providing 50 percent to illuminate the working area. The lamp
head angle of elevation shall be adjustable at a pivot in the mounting arm and the position locked with a
round knurled locking knob. The lamp head shall incorporate heat-dissipating fins and be no more than 5
1/4" deep by 3 3/8" high by 15" wide. Lamp head and mounting arm shall be powder coated white. The
floodlight shall be UL listed as a scene light for fire service use.
Two (2) 12-volt, water proof switches shall be wired through a 240-volt relays and shall be located on the
pump operator's panel. The switches shall control a 240 volt quartz lighting fixtures as selected.
The light head shall be mounted on a side mount push up telescopic pole. The light pole shall be anodized
aluminum and have a knurled twist lock mechanism to secure the extension pole in position. The extension
pole shall rotate 360 degrees. The outer pole shall be a grooved aluminum extrusion and qualify as an NFPA
compliant handrail. The pole mounting brackets shall have a 3 1/2" offset. Wiring shall extend from the pole
bottom with a 4' retractile cord.