Proposal Number PSDF #P09-0004
ELECTRIC CORD REEL
One (1) Hannay model ECR1616-17-18 electric rewind cord reel(s) shall be supplied and installed.
The cable reel(s) shall be a 12-volt electric rewind type.
One hundred fifty feet (150') of 10/4 SO (black) cord shall be installed on one (1) reel(s), complete with an
HS-3 ball stop.
One (1) Akron junction box, model EJB shall be provided. The junction box is to be powder coated safety
yellow and be provided with rubber feet on the bottom of the box.
One (1) Akron yellow powder coated mounting bracket, model EJB-VMT is to be shipped loose with the
apparatus for final installation by the department.
There shall be four (4) L5-20 125 Volt AC twist lock outlet with spring loaded cover.
CAPTIVE ROLLERS
There shall be a captive roller system furnished for the cord reel. The roller mounting brackets shall be
attached to guide the cord on and off the reel assembly.
REEL REWIND SWITCH
The cord reel shall be equipped with a weather resistant push button switch mounted in the relay enclosure
box within compartment that the reel is contained.
PUMP COMPARTMENT
The pump compartment shall be separate from the hose body and compartments so that each may flex
independently of the other. It shall be a fabricated assembly of stainless steel tubing, angles and channels,
which does not support the fire pump and or running boards. The pump compartment shall be mounted onto
the chassis through rubber biscuits in a four point pattern to allow for a chassis frame twist.
Pump compartment, pump, plumbing and gauge panels shall be removable from the chassis in a single
assembly. The pump compartment shall be a modular design.
A stainless steel framework shall provide the support for the mounting of the pump lower panels. Stainless
steel structure shall be provided as a support behind all control push-pull handles enabling a firm foundation
for operation of the valve control.
An upper framework shall encompass the crosslay hose bed and walk way area for operation of the deck gun.
The floor of this section shall be a bolt-on design to provide access for major repairs and or service.
RUNNING BOARDS
The running boards shall be separate from the hose body, compartments, and pump compartment so that each
may flex independently of the other and to allow water to flow freely away from the running board area.
Separation of the running boards and support structure from the hose body, compartments and pump
compartment is desired to provide field service of the running board without major repairs to the pump
compartment in the event of an accident.