Specifications

Proposal Number PSDF #P09-0004
PUMP OPERATION HOURMETER
A pump hourmeter shall be supplied. The hourmeter shall be environmentally sealed to prevent moisture
from entering the instrument. The face shall provide a display of the total cumulative hours of pump
engagement. The hourmeter shall be protected by being located inside the pump module.
PUMP PANEL LIGHTING
The pump operator's panel shall be supplied with a LED light system. LED strip lights with a stainless steel
hood shall be mounted across the top of the pump panel gauges and controls.
LED strip lights with a stainless steel hood shall be provided on each side of the pump module above the side
panels.
All pump module lighting shall illuminate when the parking brake is engaged.
DRAIN DISCHARGES
The 3/4 inch drain valves shall be equipped with 90-degree fittings to direct the discharge water beneath the
pump module away from the pump operator's panel.
AIR HORN ACTIVATION SWITCH
A switch shall be located on the pump panel to activate the chassis air horn. The switch shall be a
momentary pushbutton type switch with a red cover. The switch shall be supplied with the proper
identification label.
WATER TANK LEVEL GAUGE
The apparatus shall be equipped with a Class 1 "Inteli-Tank" Tank Level Gauge, or equal, for indicating
water level. The tank level gauge shall indicate the liquid level on an easy to read LED display and show
increments of 1/8 tank capacities. The tank level gauge system shall include a pressure transducer that shall
be mounted on the outside of the tank in an easily accessible area, a super bright LED four-light display with
a visual indication at nine (9) accurate levels, and a set of weather resistant connectors to connect to the
digital display, to the pressure transducer and to the apparatus power.
FOAM TANK LEVEL GAUGE
The apparatus shall be equipped with a Class 1 "Inteli-Tank" foam tank level gauge for indicating foam
level. The foam tank level gauge shall indicate the foam concentrate level on an easy to read LED display
and show increments of 1/8 tank capacity. The foam tank level gauge system shall include:
A pressure transducer that shall be mounted on the outside of the tank in an easily accessible area. A super
bright LED four-light display with a visual indication at nine accurate levels. A set of weather resistant
connectors to connect to the digital display, to the pressure transducer and to the apparatus power.
PUMP MANUFACTURER AND MODEL
The pump shall be a Hale Q-MAX model midship pump 2,000 gpm single stage.