Specifications
Proposal Number PSDF #P09-0004
One (1) chrome plated, Class 1, 2-1/2" NSTF to 1-1/2" NSTM rocker lug reducer with cap and chain shall be
furnished
The second discharge on the right (curb) side of the pump panel shall contain:
A 3" discharge shall be provided. The discharge outlet shall have a 3" quarter-turn swing-out valve. The
discharge shall be provided with chrome plated 30-degree discharge elbow with 3" NST male threads that
extends through the pump panel.
One (1) 3" NST Female Rigid Rocker to 5" Storz hard coated aluminum adapter shall be provided with a 5"
Storz cap and chain with a suction gasket shall be provided.
REAR PRECONNECT - RIGHT SIDE
There shall be one (1) 2-1/2" discharge outlet located on the passenger side rear of the body below the hose
bed. The discharge outlet shall be plumbed with 2-1/2" ID, Schedule 40 stainless steel pipe and high
pressure hose and have a 2-1/2" quarter-turn, swing out valve with control on pump operator's panel. There
shall be a chrome plated 2-1/2" NST adapter that extends through the rear of the body.
BOOSTER HOSE REEL
See front bumper section on page #7
DRAIN DISCHARGES
The 3/4 inch drain valves shall be equipped with 90-degree fittings to direct the discharge water beneath the
pump module away from the pump operator's panel.
AKRON BALL VALVES
All ball valves shall be manual control 1/4 turn Akron heavy duty valves with stainless steel ball unless
specified otherwise.
The valves shall have an all cast brass body with flow optimizing stainless steel ball, and dual polymer seats.
The valve shall be capable of dual directional flow while incorporating a self- locking ball feature using an
automatic friction lock design and specially designed flow optimizing brass ball. The valve shall not require
the lubrication of seats or any other internal waterway parts, and be capable of swinging out of the waterway
for maintenance by the removal of six bolts.
FOAM SYSTEM
A Hale "FoamLogix 2.1A" 2.1 GPM foam system shall be supplied on the apparatus. The apparatus shall be
equipped with an automatic electronically controlled, direct injection, rotary gear pump, discharge side foam
proportioning system. Foam proportioning operation shall be based on direct measurement of water flow,
and remain consistent within the specified flows and pressures.
The foam system will operate as a Class A system.