Specifications
Proposal Number PSDF #P09-0004
1. One (1) 10' folding attic ladder, Alco-Lite #FL-10
2. One (1) 14' Fresno ladder, Alco-Lite #CJL-14
3. Two (2) 16' roof ladders, Alco-Lite #PRL-16
4. One (1) 24' two section extension ladder, Alco-Lite #PEL-24
5. One (1) 35' three section extension ladder, Alco-Lite #PEL-35
1. One (1) 12' fiberglass pike poles
2. One (1) 10' fiberglass pike poles
3. One (1) 8' fiberglass pike poles
4. One (1) 6' fiberglass pike poles
5. Two (2) 4ā fiberglass pike poles with āDā handles
AERIAL OUTRIGGERS AND STABILIZER SPECIFICATIONS
Aerial Set-Up Requirements
With the stabilizers set, the aerial device shall be capable of being raised from the bedded position to
maximum elevation and extension and rotated 90 degrees. Two or more of these functions shall be permitted
to be performed simultaneously. These functions are required to be completed within 75 seconds or less, no
exceptions.
Extension Beams
The extension beams shall entirely enclose the extension cylinders to prevent damage to the rods and hoses.
Each outrigger shall be controlled independently, which can extend and lower the outrigger at the same time
or raise and retract the outrigger at the same time.
A double box design shall enclose the jack cylinders completely to protect the rods from damage that could
result from exterior circumstances.
Jack Cylinders
The jack cylinders shall have pilot operated check valves for both the raised and lowered positions. Each
jack tube shall be drilled for mechanical pin locks for a safety backup.
The outrigger jack cylinders shall be mounted so they can be removed from the top of the outrigger jack
tube. Jack cylinders that are removed from the bottom of the outrigger jack tube will not be accepted.
Outrigger Deployment Alarm and Warning System
The outrigger deployment alarm, of not less than 87 DBA, shall sound at all times while the outrigger master
switch is in the on position and stops sounding only when the outrigger switch is turned off. The audible
alarm shall warn personnel that outrigger movement is possible at any time the switch is on.
A red LED flashing light shall be mounted to the inside of the vertical outrigger jack beam. The aerial
master switch shall activate the lights.
An amber indicator light shall be located on the outrigger control panel for each outrigger to indicate when
the outrigger jack is supporting enough load to be in firm contact with the ground.