Installation Manual

5
Specications:
No. Name Parameters
1 Video input 0.7Vpp with 75 Ω impedance
2 Synchronized signal strength 3‐5Vpp with 5K impedance negative pulse synchronization.
3 RGB resolution By changing DIP4 user can select HD/VGA or normal
HD : 800X480 or VGA :640X480
Normal NTSC‐vertical 240 (or 234)
4 Av1, Av2, cam video 0.7Vpp with 75 Ω impedance
5 Av1, Av2, cam format NTSC/PAL/SECAM Automatic switch
6 Normal power 4.8W [0.4A @12V]
7 Stand by current < 10mA
8 Trigger level threshold (Reverse and
switching)
>5V trigger
9 Output current of additional control
port 1.2.7
Maximum current of 2A.
10 Operating temperature range ‐40 +85C
11 Dimensions 15.6 X 9.2 X 2.2 Cm
For Technical Support Please Call 1- 800-323-4815.