Users Manual

30
USER'S MANUAL
At the end of the procedure the results of the analysis of the fronts of the interfaced source will be
shown. By selecting Module the frequency trend of the signal will be displayed (Master EQ), the curve
calculated to compensate for the present equalization (Master De-Eq), the trend of the sum (SUM), in
addition the software will calculate the trend of any input lters (XOVER) available. Clicking on each
individual chart on the front, it will be possible to enlarge the trend of each individual front. It is also
possible to display in this window the presence of time delays on the source if analysed, if any.
By selecting Suggested All Pass, instead, the phase compensation of the fronts suggested by the
software will be displayed. It is applied via All-Pass rst and second order lters according to the OEM
source algorithm. In addition the software will display the electric response provided by the fronts
selection, to inform the user about the suggested compensation. It will be possible after the end of
the "I / O Conguration Wizard" to optimize the positioning of these lters or enable them
(see sect. 8.8.1)
- Press BACK to go back to the previous step.
- Press NEXT to continue with the conguration.
- Press CANCEL to exit.
7. INPUT Analysis Dashboard.
7