3.
FINALIZE TO BIT ONE HD VIRTUOSO
: this function enables the
loading of all the parameters selected while conguring the
bit One HD Virtuoso microprocessor internal memory, allowing
it to work without being connected to a PC. When selecting
the Finalize to bit One HD Virtuoso function, the software
noties that the data previously saved in the bit One HD Virtuoso
will be overwritten.
- Select YES to load the data saved in the bit One HD Virtuoso,
overwriting the previously saved data, if any.
- Select NO to interrupt the process.
WARNING: before disconnecting the bit One HD Virtuoso from the PC or each time that you exit the PC
software after modifying the system conguration, always run the Finalize to bit One HD Virtuoso
procedure. If you do not follow these instructions all the data entered will be lost.
4.
Synchronize, PC -> bit One HD Virtuoso or
PC <- bit One HD Virtuoso
:
these functions synchronize the PC with the bit One HD Virtuoso.
If a dialog box as the one to the right of this page shows up, it
means that for some reason communication between the PC
and the bit One HD Virtuoso has been interrupted. To restore the
communication select:
PC -> bit One HD Virtuoso. The PC loads the settings selected
so far in the bit One HD Virtuoso.
PC <- bit One HD Virtuoso. The PC loads the settings
previously stored in the bit One HD Virtuoso on the PC software.
WARNING: this operation can not guarantee that the data are always retrieved.
If the operation is not successful:
1. exit the bit One HD Virtuoso software.
2. turn the bit One HD Virtuoso off.
3. turn the bit One HD Virtuoso on.
4. launch the bit One HD Virtuoso software again.
By performing these actions, synchronization will be restored but the selected settings will be lost.
5. Check for updates: it enables the connection to the website www.audisonbitdrive.eu to check if any
software / rmware updates for the bit One HD Virtuoso are available (see section 9.3). To perform this
operation, your PC has to be connected to the internet.
7.
Register produc
t:
this function requires an internet connection and opens the default browser to the page for
registering the product and creating a personal account in the “bit Drive” portal. This operation only needs to
be performed once; then you can access your account through the Account Login
(see section 9.3)
.
6.
Check for Updates on Startup: when enabled, the software automatically checks the availability of new
Firmware/PC software updates each time the program is started
(see section 9.3)
.
8.
Update Firmware: function to update the bit One HD Virtuoso rmware (see section 9.3).
9.
Reset Default Answer: it restores the display of the warning
messages if they have been disabled by ticking
“Don’t show me again”.
10.
Restore Factory Defaults: it entirely resets the bit One HD Virtuoso
back to its default settings, cancelling all the data previously
saved in the bit One HD Virtuoso (see section 8.2.2).
WARNING: during this procedure the bit One HD Virtuoso
RCA / AD LINK - AC LINK outputs to the ampliers should be
disconnected.
8