AUDIX M40 INSTALLATION GUIDE Thank you for choosing Audix! Our products are designed to provide you with many years of reliable service. Please read this manual before using the system for optimal installation and operation.
M40 EXPLODED VIEW: SLOTTED MOUNTING NUT BRASS STRAIN RELIEF FOR OUTER CABLE JBM40 PLENUM RATED BOX CEILING TILE WITH 5/8″ HOLE M40 M40 JUNCTION BOX ASSEMBLY BOTTOM VIEW OF JUNCTION BOX • • • • • • • • DRILL 5/8 INCH HOLE IN THE CEILING TILE. OPEN JMB40 BOX LID AND PLACE BOX ON TOP OF 5/8 INCH HOLE IN THE CEILING TILE. (SEE #1) PLACE JBM40 BOX OVER THE CEILING TILE 5/8 INCH HOLE. INSERT M40 THREADED CEILING MOUNT THROUGH CEILING TILE AND INTO THE JBM40 BOX SECURELY TIGHTEN THE KNURLED NUT.
INSTALLATION AND WIRING INSTRUCTIONS FOR AUDIX M40 CEILING MICROPHONES 1 2 Open lid of JBM40 box and place on top of ceiling tile drilled hole. 3 Insert ceiling mount through ceiling tile hole, and into JBM40 box then tighten the knurled nut. 4 3 21 Insert plenum wire through strain relief nut, then connect to the Phoenix terminal. Wiring: 1 = Ground 2 = Blue (+) 3 = Yellow (-) Recommended cable: Belden 9451P - .124” O.D. or Belden 82761 - .116” O.D. 5 3 21 6 Connect Phoenix terminals.
SEISMIC RESTRAINT INSTRUCTIONS CABLE EXPLODED VIEW: PLENUM RATED CABLE PLENUM RATED BOX Wrap the cable around a beam, eyebolt or hanger. Next, slip the cable through the top of cable stay barrel pulling excess cable until taut. CABLE g g g PUSH PIN IN TO RELEASE g g g g CABLE STAY BARREL g CABLE RELEASE PIN g g To release cable, depress the cable release pin on top, to release the loop, or on bottom, to extend cable length. LITJB405570 ver. 2.