Specs

Transducer Type Dynamic
Frequency Response 48 Hz - 19 kHz
Polar Pattern Hypercardioid
Output Impedance 150 ohms
Sensitivity 0.8 mV / Pa @ 1k
Capsule Technology VLM Type C
Off Axis Rejection > 30 dB
Maximum SPL ≥144 dB
Power Requirements None
Connector Switchcraft® male
XLR connector
Polarity Positive pressure on diaphragm
produces positive voltage on pin 2
relative to pin 3 of output
XLR connector
Housing / Finish Zinc Alloy /
Black E-coat
Weight 307 g / 10.8 ounces
Length 176 mm / 6.9 inches
SPECIFICATIONS:
ARCHITECTS AND ENGINEERS SPECIFICATIONS:
The microphone shall be of the dynamic type and the polar pattern of the microphone
shall be hypercardioid. The nominal output impedance shall be equal to 150 ohms at
1 kHz.The microphone shall have a sensitivity of 0.8 mV / Pa at 1 kHz and a sound
pressure level ≥144 dB. The microphone body shall be of die cast zinc alloy and the
grill cap shall be steel wire mesh. The overall dimensions shall be 23 mm in diameter
at the base, 53 mm in diameter at the widest point on the grill and 176 mm in length.
The microphone shall be the Audix OM7.
OPERATION:
The OM7 is a low impedance microphone and should be plugged into the “mic level”
input of your console, mixer, or recording device. Please note that your microphone
does not require phantom power and will not be effected in any way by phantom
power should it be running simultaneously while the microphone is in operation. Avoid
plugging or unplugging the microphone from the PA system unless the channel is
muted or the volume of the system turned down. Failure to do so may result in a loud
“popping” noise which could seriously damage the speakers in the PA system.
USER TIPS:
The OM7 is designed with an unconventionally low output level; this means that the
gain will have to be compensated on the mixing console or mic preamp. The OM7 has
the tightest pick-up pattern of any microphone on the market in order to help eliminate
sound from other instruments on stage from “bleeding” into the microphone. For best
results, it is important to sing directly into the mic as close as possible (within 1-inch)!
When using oor monitors, position the microphone so that it is parallel to the oor.
When using multiple microphones on a live performance stage, allow a distance of 2-3
feet between mics to avoid phase issues.
*Further miking techniques may be found on our website at www.audixusa.com
www.audixusa.com Call: 503-682-6933 Fax: 503-682-7114
Audix Corporation 9400 SW Barber Street, Wilsonville, OR 97070
SERVICE AND WARRANTY:
This microphone is under warranty for
a period of 5 years from any and all
manufacturing defects. Should your
microphone fail in any way, please con-
tact the Audix Service department at
503-682-6933. A Return Authorization
number is required before returning
any products.
CARE AND MAINTENANCE:
The OM7 is manufactured to exacting specs
with roadworthy construction. However, the
capsule is highly sensitive and should be
handled with care. Avoid extreme temperatures
and be sure to store your microphone in the
pouch provided when not in use. Moisture of
any kind can adversely affect the sound and
performance of your microphone.
FREQUENCY / POLARS:
To register your
microphone, please visit
www.audixusa.com
***All specications subject to change without notice.
DIMENSIONS (mm):
OM7