Technical data

COMfortel 1400 - Firmware Version 1.4 - COMfortel Set V3.6 - Operation and Configuration V01 04/2014 321
Functions
Waiting Field Function
Configuring and Operating Function Key for Switching Waiting Field Reception On/Off
Using COMfortel Set to Configure the Function Key for Switching Waiting Field
Reception On/Off
1. Open the page Function keys > Assign function keys.
2. Click the Level 1 tab.
Important: Configuring this function is only possible on the first level.
3. Right-click the function key you want to assign.
A function selection dialogue opens.
4. Select the Waiting field reception function.
The current settings for defining the key are displayed.
5. In the Kind of switching list field, select one of the following options:
6. In the Key name entry field, enter a name for the key. Possible entries:
Clicking automatically enters the default name in the entry field.
Note: The key name is used for printing the label.
Further steps:
– Save your configuration before closing.
Requirements for operating the function:
– The telephone has been selected in the PBX as a waiting field reception
switch off: Disables the waiting field reception.
switch on: Enables the waiting field reception.
switch over: Press the key to switch the waiting field reception function on or
off.
Up to 16 digits
Digits and characters