Clarity MONITOR EQ248C USER GUIDE
CONTENTS Getting Started ........................................................................................... 2 Setting up your Monitor ........................................................................... 3-6 Connecting your Monitor to your computer ............................................. 7-9 Using your Monitor ................................................................................... 10 Operator Interface .........................................................................
GETTING STARTED Your Monitor is designed to work seamlessly with Windows devices that contain a HDMI, DVI, or VGA input.You also have a USB 2 in 1 Hub. It features a 24” LED/LCD backlit screen with 2560 x 1440 resolution.(Only through DVI,other input just up to 1920 x 1080).
SET-UP YOUR MONITOR: STEP ONE Check to make sure your packaging includes each of the following: 1. Monitor / Monitor base 2. Signal Cable (VGA cables) 3. Power cord 4.
SET-UP YOUR MONITOR: STEP TWO Connect your monitor to the base. Unpack the monitor and attach the base. For snap-in models tools and fasteners are not required. If screws have been provided with your monitor please connect the base as follows: 1. Cover an even stable surface with a soft cloth. 2. Place the LED/LCD Monitor unit face-down on the cloth,rotate and fit the stand onto th botton of the LED/LCD Monitor units as shown,until the stand is firmly fixed.
SET-UP YOUR MONITOR: STEP THREE Follow these instructions to adjust your monitor’s viewing angle: Hold the base of the monitor with one hand (to keep the screen from shaking) Using your other hand, grab the side or top of the monitor and tilt the screen forward or backwards. You may adjust the angle of the display from 5° (forward) to 20° (back). Do not touch the actual screen when you adjust view angle of the monitor as this may cause damage or scratching.
SET-UP YOUR MONITOR: STEP FOUR Connect your monitor to a power source. 1. Connect the output cable from the AC Power Adapter (“The Brick”) to the DC Power In connector (flat side of connector towards the cabinet rear) on the monitor. 2. Plug in the IEC Power Cord to the input side of The Brick and your 100/120V or 220/240V AC grounded power outlet using the provided power cord. NOTE: using the device with voltages other than those listed above may cause permanent damage to the monitor.
CONNECT YOUR MONITOR TO YOUR COMPUTER OR DEVICE Plug in the Cable connecting your desktop, laptop or other device to your monitor. Notes: • If you want to use for WQHD (2560 x 1440), only through DVI Port,VGA & HDMI just can support 1920 x 1080. • If you are using the DVI or VGA video cable, be certain to tighten down the grounding screws on the connector (on both ends of the video cable). Turn on the source device then turn on the monitor (push power button on the cabinet).
CONNECTING YOUR MONITOR: FOR YOUR REFERENCE 1 Port Connections (Left to Right) • DVI • HDMI • VGA • Earphone Out • AUDIO IN • DC (power) 3 DVI HDMI VGA Earphone Audio DC Mainframe computer 8
CONNECTING YOUR MONITOR: FOR YOUR REFERENCE When using a DVI cable, make sure it is a dual link cable, as only a dual link cable will support 2560 x 1440 Resolution. If using a DVI to HDMI cable, the DVI end must be dual link.
USING YOUR MONITOR Turn on your monitor by using the ON/OFF power key (located on the front, bottom edge). The power ON indicator LED should be lit. In the following section you will learn how to adjust your monitor’s settings.
OPERATOR INTERFACE AUTO Key: This key is an exit key (exit OSD menu) when OSD menu is active. MENU Key(Menu/Select): Activate OSD menu or confirm function adjustment. VOL-Volume control key: 1.Press this key to decrease volume. 2.Press this key to adjust the options to move left. VOL+Volume control key: 1.Press this key to increase volume. 2.Press this key to adjust the options to move right. UP KEY/ECO Adjustment Key: When OSD menu is active, press this key to adjust the options move up.
OPERATOR INTERFACE DOWN Key/DCR Adjustment Key: When the OSD menu is active, press this key to adjust the options move down.
ADJUST YOUR MONITOR’S SETTINGS 1. Press the “MENU” key to activate the OSD interface. 2. Use the “UP” or “DOWN” Keys to browse the main functions. 3. In order to select a function press the “MENU” key. 4. If the function you need has a sub-menu use the “UP” or “DOWN” keys to navigate it, then press “MENU” to select. 5. Press “UP” or “DOWN” to adjust the selected function. 6. Click the “AUTO” button to save and exit.
ADJUST PICTURE 1. Press the “MENU” key 2. Press the “UP/DOWN” buttons and browse to “PICTURE” in the main menu, then press “MENU” to select it. 3. Use the “UP/DOWN” keys to browse BRIGHTNESS, CONTRAST,GAMMA click “MENU” to select and adjust any of these. 4. Use the “VOL + / VOL -” keys to adjust the settings. 5.
ADJUST COLOR 1. Press the “MENU” key 2. Press the “UP/DOWN” buttons and browse to “COLOR” in the main menu, then press “MENU” to select it. 3. Use the “UP/DOWN” keys to browse PRESET,RED,GREEN,BLUE click “MENU” to select and adjust any of these. 4. Use the “VOL + / VOL -” keys to adjust the settings. 5.
ADJUST TRACKING 1. Press the “MENU” key 2. Press the “UP/DOWN” buttons and browse to “TRACKING” in the main menu, then press “MENU” to select it. 3. Use the “UP/DOWN” keys to browse HORIZONTAL,VERTICAL,CLOCK, PHASE,SHARPNESS click “MENU” to select and adjust any of these. 4. Use the “VOL + / VOL -” keys to adjust the settings. 5.
ADJUST VOLUME 1. Press the “MENU” key 2. Press the “UP/DOWN” buttons and browse to “VOLUME” in the main menu, then press “MENU” to select it. 3. Use the “UP/DOWN” keys to browse VOLUME, MUTE click “MENU” to select and adjust any of these. 4. Use the “VOL + / VOL -” keys to adjust the settings. 5.
ADJUST SETUP 1. Press the “MENU” key 2. Press the “UP/DOWN” buttons and browse to “SETUP” in the main menu, then press “MENU” to select it. 3. Use the “UP/DOWN” keys to browse LANGUAGE,OSD HORIZONTAL, OSD VERTICAL,OSD TIMER, WHITE BALANCE, DCR,4:3 OR WIDE, INPUT SELECT,FACTORY RESET click “MENU” to select and adjust any of these. 4. Use the “VOL + / VOL -” keys to adjust the settings. 5.
TROUBLESHOOTING Power pilot lamp is dim Check to make sure the power is turned ON Check to make sure the power cord is securely connected to both the monitor and the socket.
TROUBLESHOOTING Picture is not in the middle or incorrect size Adjust CLOCK and FOCUS or hot keys (AUTO) The images have color shading (white looks not pure white) Adjust RGB color or choose new color temperature Weak brightness and contrast Monitor brightness may be reduced due to over use. The monitor may need service. Please send monitor to authorized service organization for repair.
SPECIFICATIONS Panel Display Equipment Dimensions Dot Pitch (mm) Panel Resolution Clarity Resolution Panel (LED/LCD backlight) 24” 0.233 x 0.233 1920 x 1080 2560 x 1440 (Just through DVI) Input Signal VGA DVI HDMI D-Sub 15 pin Connector DVI-D Connector HDMI Connector Frequency HFR (Horizontal Frequency) VFR (Vertical Frequency) Pixel Clock Frequency PNP (Plug and Play) 30KHz 88.7KHz 60Hz 241.
SPECIFICATIONS Power Equipment 12V 3A AC Adapter: 100-240V,50-60Hz Ambient Temperature Humidity Operating temperature:0~50°C Storage temperature:-20~60°C Operation relative humidity: 10~85% Dimensions (mm) 640(L) x 150(W) x 470(H) mm Weight (Net) 4.
PRESET DISPLAY MODES Resolution HFR(KHz) VFR(Hz) DOS Mode 720 x 400 31.469 70 VGA 640 x 480 640 x 480 640 x 480 31.469 37.861 37.500 60 72 75 SVGA 800 x 600 800 x 600 800 x 600 37.879 47.20 46.875 60 72 75 XGA 1024 x 768 1024 x 768 1024 x 768 48.363 56.476 60.023 60 70 75 SXGA 1280 x 1024 1280 x 1024 63.981 79.976 60 75 WXGA+ 1440 x 900 55.674 60 WSXGA+ 1680 x 1050 59.
PRESET DISPLAY MODES Resolution HFR(KHz) VFR(Hz) Full HD 1920 x 1080 67.50 60 WQHD 2560 x 1440 88.70 30 * WQHD (2560x1440) 30Hz only for DVI Port CARE & SAFETY Attention: Any unauthorized modifications or changes may cause the monitor to not work properly. The manufacturer is not responsible for radio or image interference caused by unapproved modifications. Users should solve interference issues by themselves.
CARE & SAFETY Usage It is normal for your monitor to “blink” the first time you use it. If this occurs simply turn your monitor off, then on again. The effective screen pixels of your monitor should read 99.99% or more, pixel or brightness loss should be less than 0.01%. During normal usage your monitor should not have pixel residue. However, when the same static picture is showed a long time before changing the image, the previous image may remain, which is called “the shadow”.
CARE & SAFETY Cleaning & transport Keep the original box and other packing material in the event that you need to ship your monitor. To clean your monitor use a soft, dry cloth and only cleaners intended for use with a screen or display. Cleaners with alcohol or acetone will damage your screen. Any marks on the monitor should be cleaned gently so as to prevent damage. For your safety, please un-plug power cord before cleaning.
Warranty Statement For AURIA LED/LCD Monitor - EQ248C Including those Sold within North America AURIA warrants this product to be free from defects in material and workmanship for a period of twelve months after the original date of consumer purchase. During this period, Auria will, at its option, either repair the defective product with new or rebuilt parts, or replace it with a new or rebuilt product at no charge except as *stated below.
This limited warranty does not cover any losses or damages that occur as a result of: ● Shipping or improper installation or maintenance ● Misuse ● Neglect ● Adjustment by non-authorized sources ● Any cause other than ordinary usage ● Repair, modification, installation of options or parts by anyone other than an Auria ASC ● Improper environment ● Excessive or inadequate heating or air conditioning or electrical power failures, surges, or irregularities This one year warranty does not cover any of the produc
AURIA OBLIGATIONS AND YOUR REMEDIES HEREUNDER ARE SOLELY AND EXCLUSIVELY AS STATES HERE. AURIA LIABILITY, WHETHER BASED ON CONTRACT, TORT, WARRANTY, STRICT LIABILITY, OR OTHER THEORY, SHALL NOT EXCEED THE PRICE OF THE INDIVIDUAL UNIT WHOSE DEFECT OR DAMAGE IS THE BASIS OF THE CLAIM. IN NO EVENT SHALL AURIA BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF USE OR FACILITIES OR EQUIPMENT OR OTHER INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGE.
EQD is located at: 3309 E. Miraloma Avenue Suite 107 Anaheim, CA 92806 For Customer Service please call 877-375-1065 or visit www.eqdcorp.