Installation manual

DIDO Jr. Installation Manual
30
13 RS-232 Protocol
Serial Control Setup: 115k 8N1 (Default)
Baud Rate: 2400 – 115k (Selectable).
Serial Connector Type: 9 to 6 pin RS 232 cable (NULL).
Note: this cable is supplied by the manufacturer.
The DIDO Jr. is addressable. Units will be addressable from 000-254.
Address 255 or *** is reserved for broadcasting.
COMMAND FORMAT
:
[Prefix][Address][Command][n][m] [<CR>]
? QUERY COMMAND (Does not have to be Case Sensitive)
! COMMAND (Does not have to be Case Sensitive)
~ RESPONSE (ALL RESPONSES ARE CAPITALS)
ADDRESS 000 – 254 (255 or *** is used for Broadcasting)
COMMAND ASCII FORMAT (See Command List)
n, m: variables
<CR> 0D (hex) or 13 (decimal)
Note
:
If a command doesn’t require variable(s), then nothing should be entered.
If a command does have variable(s), the response will include variable(s).
Example:
!001KEY_ZOOM<CR> Will tell unit addressed at 001 to carry out the Zoom command.
~001KEY_ZOOM<CR> Response from the DIDO Jr..
!***KEY_POWER<CR> Will tell all units to toggle the power.
!000HPOSIT <n> <CR> Set horizontal position at n.
~000HPOSIT <n> <CR> Response from DIDO Jr..
COMMAND LIST:
!
COMMANDS FUNCTION NOTE
1 KEY_P1 PRESET 1
2 KEY_P2 PRESET 2
3 KEY_P3 PRESET 3
4 KEY_P4 PRESET 4
5 KEY_NUM0 NUMBER 0
6 KEY_NUM1 NUMBER 1
7 KEY_NUM2 NUMBER 2
8 KEY_NUM3 NUMBER 3
9 KEY_NUM4 NUMBER 4
10 KEY_NUM5 NUMBER 5